Updating TIM/PCM calibration data
8-78
Chapter 8: Service & maintenance
98-137654-A
8.6
Updating TIM/PCM calibration data
After installing a new TIM (Television Interface Module) or PCM
(Pedestal Control Module) you must update the calibration data.
The ACU does not know which of the two modules (PCM or TIM) has
been replaced. The ACU needs to know which set of data to keep.
You must select the
module that was not exchanged
so the
calibration data can be copied to the module that was exchanged
during service.
1. Enter the web interface (http://192.168.0.1) and click
SERVICE
>
XIM DATA
. A screen similar to the one in the figure below will
appear:
2. The figure shows at
Unit-no
Unit-Serial-Number for the PCM,
because this module was exchanged during service. In this case
the user must press the select button below the TIM module in
order to copy the current calibration data to the new PCM
module.
3. Click
Select
, then a warning will appear.
4. Click
OK
to continue, the data is copied into the replaced module.
5. Click
Refresh
. When the XIM data has been successfully copied
from one module to the other, the web interface displays a
Figure 8-101: Updating TIM/PCM calibration data (example)
Important
Select always the XIM data for the module that
was
not
exchanged.
Figure 8-102: XIM data, warning
Figure 8-103: XIM data not ready
SAILOR100TM.book Page 78 Tuesday, January 29, 2013 2:44 PM
Summary of Contents for 100
Page 1: ...TRAINING INSTALLATION SERVICE MANUAL SAILOR 100 Satellite TV ...
Page 2: ......
Page 13: ...Table of contents 98 137654 A xi SAILOR100TM book Page xi Tuesday January 29 2013 2 44 PM ...
Page 14: ...Table of contents xii 98 137654 A SAILOR100TM book Page xii Tuesday January 29 2013 2 44 PM ...
Page 215: ...Appendices SAILOR100TM book Page 1 Tuesday January 29 2013 2 44 PM ...
Page 216: ...SAILOR100TM book Page 2 Tuesday January 29 2013 2 44 PM ...
Page 254: ...Glossary Glossary 4 98 137654 A SAILOR100TM book Page 4 Tuesday January 29 2013 2 44 PM ...
Page 261: ......