Appendix C: Grounding and RF protection
128
RF interference
C.10 RF interference
Interference induced from nearby RF transmitters might cause system failures
and in extreme cases permanent damage to the SAILOR FleetBroadband
equipment. If problems with interference from HF transmitters are
encountered, it is advisable to mount ferrite clamps on the coax cable in order
to provide suppression of induced RF. The ferrites will have no effect on the
differential-mode signals but increases the impedance in relation to common-
mode RFI.
C.10.1 Recommendations
1-5 pcs. hinged clamp cores (e.g. the RFC or SFC series from Kitagawa)
mounted on the antenna cable near the antenna.