Functional unit workshop service
VHF 5000 System
3-14
•
Use a small amount of sealing compound (must not
contain acid) to provide support of the coil to the
stand off.
1007
•
Use a small amount of sealing compound (must not
contain acid) to provide support of the ferrite coil
and power plug wiring to the E-profile.
•
Reinstall the cover on top of the PSU module and
secure it using the two (2) screws.
•
Position the DC power plug in the rear chassis of
the radio and secure it using the two (2) socket
screws.
Fig. 18