UAIS DEBEG 3400, Electronics Unit
ED3047G142 / 08 (2004-06)
Technical Manual
6 Repair/Maintenance
6.1 Trouble Shooting
t_ue_e07.fm / 21.06.04
54
Test of the UAIS DEBEG 3400 Output
1.
Power Down the system
2.
Connect the AIS Primary Display Port TB7 and TB8 additionally to an indicator serial interface (TB1)
of the radar. If there is a free input, this one should be used. If all inputs are used, one of them must
be disconnected. Figure 6-1 shows the connection to the serial interface No. 4 as an example.
Fig. 6-3
Cable connection for the interface monitoring AIS > Radar
3.
Power on the radar. Configure the concerned indicator serial interface by means of the System Main-
tenance Manager as follows
Path:
Configure > Radar > Indicator > Indicator x > Serial Interfaces > Serial I/O x
Parameters:
-
Driver, set to NMEA183 (IEC 61162-1/2)
-
Baud Rate, set to 38400
-
Wind, set to Connected (if the interface has been used for a ship’s sensor with NMEA183
(IEC 61162-1/2) protocol beforehand, it is not necessary to modify this parameter.)
4.
The Serial I/O Monitor must be started.
Path:
Service > Indicator > Serial I/O Monitor
Select the used interface from the drop down list and mark the check box Rx. Start the monitoring
by clicking on Run. The protocol can be saved on a diskette.
Analog Interface
Interconnection Board
RADARPILOT/CHARTRADAR 1000
UAIS DEBEG Electronics Unit
Primary Display Port
8
10
16
Output -
AIS RxD, Input -
RxD4, Input +
AIS RxD, Input +
RxD4, Input -
Input -
AIS TxD, Output -
Input +
GND
AIS TxD,
GND
Connector 2
TB
TB1 Indicator Serial Interface 4
6
14
5
1
15
16
7
11
17
z_ue
_026.
eps