30
degradation errors. Do not compare your readings obtained from sources
such as the internet, radio, television or newspapers. They are in a different
location and typically update once per hour.
The purpose of your weather station is to measure conditions of your
surroundings, which vary significantly from location to location.
The profession weather station supports up to eight remote
thermo-hygrometer sensors. Each of the eight sensors can be calibrated.
9.1 Calibration of Temperature Mode
In normal mode, press and hold the
SET
and
C
keys at the
same time for five seconds to enter the temp calibration mode. The indoor
temperature will begin flashing.
Press the
C
key or
MAX/MIN/-
key to increase or decrease the
temperature reading (in increments of 0.1). Press and hold the
C
key or
MAX/MIN/-
key for three seconds to increase or
decrease rapidly.
Press the
ALARM
key to reset current value.
Press the
SET
key switch to outdoor Temperature.
To exit the temperature calibration mode at any time, press the
SNOOZE/LIGHT
button on the top of the display console. If no operation is
performed, the calibration mode will timeout in 30 seconds.
9.2 Calibration of Humidity Mode
In normal mode, press and hold the
SET
and
MAX/MIN/-
keys at the same
time for five seconds to enter into the humidity calibration mode. The indoor
humidity will begin flashing.