15
2.
Rainfall.
Press the
C
or
MIN/MAX/-
key to toggle between 1h, 24h, week,
month and total.
To clear the total rain, press the
C
or
MIN/MAX/-
button until total rain is
displayed. The total rain will flash. Press and hold the
SET
button for three seconds until
total rain reads 0.0.
3.
Absolute Pressure and Relative Pressure.
Press the
C
or MIN/MAX
/-
key
to toggle between absolute pressure and relative pressure.
4.Outdoor dew point .
Press the
C
or
MIN/MAX/-
key to toggle between
temperature, dew point and feels like
7.2 Set (Program) Mode
While in Normal Mode, Press
and hold
the
SET
key for at least three seconds to enter the
Set Mode. The first setting will begin flashing. You can press the
SET
key again to skip
any step, as defined below.
Note:
In the Set mode, press the [+] key or [
-
] key to change or scroll the value. Hold
the [+] key or [
-
] key for three seconds to increase/decrease rapidly.
Note:
To exit the Set mode at any time, press the
SNOOZE
button of the display
console.
1.
12/24 Hour Format (default: 12h):
.Press the
SET
key again to adjust the 12/24 hour
format setting (FMT). Press the [+] key or [
-
] key to change between 12 hour and 24
hour format.
2.
Change Hour.
press the
SET
key again to set the hour. Press the [+] key or
[-]
key to
adjust the hour up or down. Note the PM icon is present during afternoon hours.
3.
Change Minute.
Press the
SET
key again to set the minute. Press the [+] key or [
-
] key
to adjust the minute up or down.
4. Date Format (default: MM-DD): Press
the
SET
key again to enter the day/month
format mode. Press the [+] key to switch between
M-D, D-M
.
5.
Change Month.
Press the
SET
key again to set the calendar month. Press the [+] key
or [
-
] key to adjust the calendar month.
6.
Change Day.
Press the
SET
key again to set the calendar day. Press the [+] key or [
-
]
key to adjust the calendar day.
7.
Change Year. Press
the
SET
key again to set the calendar year. Press the [+] key or [
-
]
key to adjust the calendar year.
8.
Max/Min Clearing (default: ON)
. Press the
SET
key again to set the max/min
clearing mode (CLR). The Max/Min can be programmed to clear daily (at midnight) or
manually. Press the [+] key or [
-
] key to switch between “Clears 24h” and Clears
Manually.
9.
Temperature Units of Measure (default:
°F
):
. Press the
SET
key again to change the
temperature units of measure (the
UNITSET
icon will be displayed). Press the [+] key
or [
-
] key to switch between °F and °C units of measure.
10.
Wind Speed Units of Measure (default: mph)
. Touch the
SET
key again to change
the wind speed units of measure . Touch the [+] key or [
-
] key to toggle the wind speed
units between m/s,bft,knots,mph or bft.
11.
Rainfall Units of Measure (default: in)
. Touch the
SET
key again to change the
Rainfall units of measure. Touch [+] key or [
-
] key to toggle the rainfall units between
mm and in.
12.
Barometric Pressure Display Units(default: inHg)
. Press the
SET
key again to
change the pressure units of measure. Press the [+] key or [
-
] key to toggle the pressure
units between mmHg, inHg or hPa.