background image

32

Manufacturer:

Sainlogic High Tech Innovation Co.,LTD

F9,De Zhong Industrial Park,

Li Pu Street,Shenzhen,China

Post:518001

Phone:+86 755 80759871

www.sainlogic.com

Email:Info@sainlogic.com

FCC ID :2ALHJ-WS0835

Summary of Contents for WS0835

Page 1: ...e Never install the weather station in a storm Warning Installing your weather station in an elevated location may result in injury or death Safety goes first Make sure your setup and preparation is s...

Page 2: ...ons LxHxW 13 x 6 x 11in 1 Foot Mounting with pole insert Dimensions 3 x 4 x 1 1 Mounting Bracket Back Plate pole mount Dimensions 3 x 3 x 1 1 Mounting Pole Dimensions 12 x 1 x 1 2 Pole mounting nuts M...

Page 3: ...GPS for wind direction calibration Adjustable Wrench Hammer and nail for Foot Mounting 3 3 Sensor Assembly Set Up The following illustration shows the full segment for Thermo Hygrometer WIND and RAIN...

Page 4: ...4 Figure 2 3 3 1 Insert batteries into the transmitter Locate the battery door on the transmitter push and open the battery compartment as show in Figure 3 Figure 3...

Page 5: ...5 Remove the battery door on the back of the sensor by removing the set screw as shown in Figure 4 Figure 4 Inserting 3xAA batteries in the battery compartment as show in Figure 5 Figure 5...

Page 6: ...es for sensors The sensor LED indicator will light for 3 seconds and then flash once per 16 seconds thereafter Each time it flashes the sensor is transmitting data Place the battery cover and push it...

Page 7: ...eception icon 10 Outdoor temperature mode 11 Daylight Saving Time 12 Time 13 Weather tendency indicator 14 Time Alarm 1 15 Time Alarm 2 16 DATE 17 Wind direction 18 Wind speed units of measure 19 Wind...

Page 8: ...sor array is at least 10 away from the console and within 100 of the console If the weather station is too close or too far away it may not receive a proper signal Remove the battery door on the back...

Page 9: ...herwise the outdoor sensor search mode will be terminated When the outdoor transmitter data has been received the console will automatically switch to the normal mode from which all further settings c...

Page 10: ...Figure 10 2 Insert the DC plug correctly as shown in Figure 11 Figure 11 3 If you want to put it on a table or cabinet opened the desk stand and turn the DC plug up until 90 degrees as shown in Figure...

Page 11: ...down until 0 degrees and closed the desk stand as shown in Figure 13 Figure 13 Note If the power adapter is plugged in BL ON will display in the time area for three seconds when powered up Conversely...

Page 12: ...in the same location about 9 8 ft apart The sensors should be within 10 the accuracy is 5 Allow about 30 minutes for both sensors to stabilize 4 Weather Station Installation 4 1 Pre Installation Check...

Page 13: ...reless communication 1 Electro Magnetic Interference EMI Keep the console several feet away from computer monitors and TVs 2 Radio Frequency Interference RFI If you have other 433 MHz devices and comm...

Page 14: ...ndicator on the wind vane that indicates South as shown in Figure 14 Align this S marker in the direction of South Step 2 Console operation is set to Northern Hemispheres NORin the time area in Locati...

Page 15: ...el North Step 2 Console operation is set to Southern Hemispheres SOU in the time area in Location division Note Console has to be location division setting so that the directions on the sensor are mat...

Page 16: ...16 Figure 15 Tighten the mounting pole to your mounting pole purchased separately with the four 5 Bolts and M5 Nuts assembly or fix on the wall with four tapping screw as shown in Figure16...

Page 17: ...n the sensor with fresh batteries Be sure to never mix old and new batteries and never mix battery types such as alkaline and lithium together 7 Console Operation Note The console has five keys for ea...

Page 18: ...door dew point Press the CHANNEL or MIN MAX key to toggle between temperature dew point and feels like 7 2 Set Program Mode While in Normal Mode Press and hold the SET key for at least three seconds t...

Page 19: ...fault m s Touch the SET key again to change the wind speed units of measure Touch the key or key to toggle the wind speed units between m s bft knots mph or bft 11 Rainfall Units of Measure default mm...

Page 20: ...in time area to clear the rainfall wind speed wind gust pressure temperature and humidity maximum values The maximum values will now display the current values Press the MIN MAX key again do not hold...

Page 21: ...he backlight will turn on permanently and display BL ON icon will be displayed for three seconds in the time field To turn off the backlight at any time Press and hold the SNOOZE LIGHT key for two sec...

Page 22: ...ZE key at any time to return to the normal mode 8 3 Setting the Alarms Press ALARM key to enter the alarm mode Next Press and hold the SET key for three seconds The first alarm parameter will begin fl...

Page 23: ...high alarm 22 Indoor temperature low alarm 23 Indoor humidity high alarm 24 Indoor humidity low alarm Note To prevent repetitive alarming of humidity there is a 4 tolerance band For example if you set...

Page 24: ...r degrades cloudy to rain The weather forecast is an estimation or generalization of weather changes in the next 24 to 48 hours and varies from location to location The tendency is simply a tool for p...

Page 25: ...ous condition is partly cloudy or Pressure is rising and the previous condition is rainy Rainy Pressure is falling and the previous condition is cloudy 9 3 Moon Phase The following moon phases are dis...

Page 26: ...anges Locations that experience frequent changes in air pressure require a higher setting compared to locations where the air pressure is typically stagnant 9 5 Feels Like Temperature Feels like tempe...

Page 27: ...ture is the same as OUT temperature 10 Specifications 10 1 Wireless Specifications Line of sight wireless transmission in open air 300ft Frequency 433 MHz Integrated Outdoor transmitter interval 16 se...

Page 28: ...h 6 7mph 22 4mph 112mph 10 whichever is greater 0 1mph Barometric Pressure 8 85 to 32 50 inHg 0 08 inHg 0 01 inHg 10 3 Power Consumption Base station display console 3 x AAA 1 5V Alkaline or Lithium b...

Page 29: ...s Unscrew the rain collector funnel by turning it 30 counter clockwise Gently remove the rain collector funnel Clean and remove any debris or insects Install the collector funnel after it has been cle...

Page 30: ...be displayed on the screen To reacquire the signal press and hold the CHANNEL button for 3 seconds and the remote search icon will be constantly displayed Once the signal is reacquired the remote sea...

Page 31: ...ion Move the remote sensor to a closer location Indoor and Outdoor Temperature do not agree Allow up to one hour for the sensors to stabilize due to signal filtering The indoor and outdoor temperature...

Page 32: ...Manufacturer Sainlogic High Tech Innovation Co LTD F9 De Zhong Industrial Park Li Pu Street Shenzhen China Post 518001 Phone 86 755 80759871 www sainlogic com Email Info sainlogic com FCC ID 2ALHJ WS0...

Reviews: