background image

VERS.2023.03.09  

 

CDM 354_MAN_EN 

Make sure the work area is well lit. Pay attention to the location of cables, pipes and rebar in 

the work area. Do not use power tools in a humid environment (rain) or near flammable 

materials. 

 

Ensure the safety of the work area 

Secure tools and work pieces securely so they do not come loose. Before starting the 

machine, make sure that all keys and other auxiliary tools are removed. Do not work in the 

wrong position and make sure you are well balanced. 

 

The noise level depends on various factors such as: material, mounting, environment, tool diameter and type, speed, feed, 

column or time of use. In the workplace, the noise level exceeds 80 dB(A). 

 

 

WEAR

 

NOISE-CANCELLING

 

HEADPHONES 

 

 

 

3  MACHINE DESCRIPTION 

CDM 354 drill motors can only be used in combination with a drill stand. The motors are 

equipped with a starting current limiter which ensures that when switching on the motor does 

not overload the network and starts smoothly. The purpose of the inside slipper clutch is to 

protect the operator and the machine. 

3.1  Function 

  To be used only with diamond drill bits for drilling holes in concrete and stony materials. 

  Use reserved only for people who have received training for this purpose. Always remain 

well concentrated during use. The tool can crash at any time. 

  To be used (class 1) in combination with plugs with earth connection and differential circuit 

breaker (PRCD) with an undervoltage release and leakage current <10 mA or isolation 

transformer (FI-Box) <10 mA and special sheet.  

  For overhead work, always use a water trap. 

  Cannot operate for more than one minute without water supply (max. 3 bar). Otherwise, 

the wear of the seals in the machine will increase considerably. 

3.2  Mains voltage 

Check whether the mains voltage corresponds to the voltage indicated on the nameplate. 

Before connecting the machine to the electrical network, check that it is in the off position. 

 

 

C

ONNECT THE MACHINE IN COMBINATION WITH

DIFFERENTIAL

 CIRCUIT BREAKER 

(PRCD)

 WITH AN UNDERVOLTAGE RELEASE AND 

10

 

M

A

 LEAKAGE CURRENT OR

 

ISOLATION

 

TRANSFORMER

 

(FI-B

OX

)

 

10

 M

A

 AND SPECIAL PLUG

 

 

 

 

 

 

 

Use of the differential circuit breaker (PRCD) 10 mA 

Summary of Contents for NORTON clipper CDM 354

Page 1: ...CDM 354 USER MANUAL Translation of the original instructions...

Page 2: ...VERS 2023 03 09 CDM 354_MAN_EN 2...

Page 3: ...OMPATIBILITY 2014 30 EU NOISE 2000 14 EC And to the European standard EN 60745 1 EN 55014 EN 61000 Valid for machines with serial number from 4503391636001 Storage location of technical documents Sain...

Page 4: ...Environment by Equipment for use Outdoors Regulations 2001 and European standard EN 60745 1 EN 55014 EN 61000 Valid for machines with a serial number greater than 4503391636001 Authorised Representati...

Page 5: ...efined 3 MACHINERY DESCRIPTION 9 3 1 Function 9 3 2 Mains voltage 9 3 3 Mounting on a drilling column 10 3 4 Gearbox 10 3 5 Training 10 3 6 Electronic protection 10 3 7 Friction clutch 10 3 8 Overload...

Page 6: ...CDM354 coring motors The type of motor is indicated on the nameplate placed on the machine 2 BASIC SAFETY INSTRUCTION 2 1 Pictograms Advice and warnings are represented by pictograms on the machine Y...

Page 7: ...The residual current of the protective ground must not exceed 10 mA Test ground protection before use Prevent water electricity contact Prevent disconnection or leakage of the water supply hose When d...

Page 8: ...hat the moving parts are working correctly that they are not jamming that no part is broken that they are correctly fitted that all the conditions that could influence the correct operation of the mac...

Page 9: ...of the inside slipper clutch is to protect the operator and the machine 3 1 Function To be used only with diamond drill bits for drilling holes in concrete and stony materials Use reserved only for pe...

Page 10: ...ck screw and dowel or with a suction plate For drilling under watering the machine must be connected to a water point using the quick coupling use clean water 3 4 Gearbox The CDM354 is fitted with a 3...

Page 11: ...s in real time the amperage the voltage the internal temperature the power and the number of hours of use It also indicates ALARM when the motor is overloaded 3 9 Statement regarding vibration emissio...

Page 12: ...11201 and NF EN ISO 3744 Machine Sound pressure level L Peq Uncertainty K Sound power level Uncertainty K Model EN ISO 11201 Sound pressure level L Peq LWeq _ Sound power level EN ISO 11201 EN ISO 374...

Page 13: ...ly Otherwise the wear of the seals in the machine will increase considerably 5 MAINTENANCE AND TROUBLESHOOTING REMOVE THE PLUG FROM THE SOCKET BEFORE CARRYING OUT MAINTENANCE OR CONTROL Regularly clea...

Page 14: ...arts list Non compliance with the information mentioned in the manual Use of the machine by unauthorized persons Use of the machine for work for which it was not designed Machine repair with non origi...

Page 15: ...clearly indicate the means of transport required such as express or by air Without specific instructions we will route parts by whatever means we deem appropriate but not always the fastest way Clear...

Page 16: ...VERS 2023 03 09 CDM 354_MAN_EN 16...

Reviews: