7
!
Attention! The tool still runs for a little while after the machine was
switched off.
For further safety instructions, please refer to the enclosure!
Before starting the machine check the correspondence between voltage
and frequency according to the data mentioned on the identification plate.
Voltage differences from + 6 % and
– 10 % are allowed.
The grinder is made in protection class II.
Only use extension cables with a sufficient cross-section. A cross-section
which is too small could cause a considerable drop in performance and an
overheating of machine and cable. The tool includes a start-up speed
limiter to prevent fast expulsion fuses from unintended responding.
Short-Time Operation
Switching-on: press the on/off switch
Switching-off: release the on/off switch
Permanent Operation ( only by using with floor guiding device )
Switching-on: press the on/off switch and, keeping it pressed, engage the
lock-on button
Switching-off: press the on/off switch and release it again
Attention!
In case of every stop of the machine or a power cut, the
lock-on button has to be released immediately by pressing
the ON/OFF switch. So you can avoid an unintentional
restart of the machine (physical hazard).
Dust which occurs during your work is hazardous to health. That is why the
concrete grinder must be used with a vacuum cleaner, and a dust mask
has to be worn. A suitable Wet/Dry Vacuum Cleaner is available as
accessory. It can directly be attached to the connection on the dust hood.
Switch the machine on and put it carefully on the surface you want to work
on. Hold the tool with both hands and work with circular or linear
movements.
For best working results: Don’t put too much pressure on the surface you
want to work on.
Electrical Connection
Switching on and off
Dust Extraction
Instruction for Use