12
3
Assembly and commissioning
Before beginning the work with the CSB1 D13, you have to assemble some parts.
3.1 Tool assembly
Only use NORTON blades with the CSB1 D13.
A blade with a maximum diameter of 500 mm can be fitted. All tools used must be selected with
regard to their maximum permitted cutting speed for the machine’s maximum permitted rotation
speed.
Before mounting a new blade, switch the machine off.
To mount a new blade, follow these steps:
Pump (for hydraulic machines) or turn the handwheel (for manual machines) until the cutting
frame is in the raised position.
Take the water nozzle off the blade guard.
Loosen the two screws maintaining the blade guard with the 19mm wrench, and open it.
Loosen the screw holding the removable outer flange with the 19mm wrench.
Remove the outer flange.
Clean the flanges and blade shaft and inspect for wear.
Mount the blade on the shaft ensuring that direction of rotation is correct. Wrong direction of
rotation blunts the blade quickly.
Replace outer blade flange.
Tighten screw with 19mm wrench.
Close the blade guard and retighten the two screws.
Reconnect water nozzle.
The blade bore must correspond exactly to the blade shaft. Cracked or damaged bore is dangerous
for the operator and for the machine.
3.2 Water cooling system
Fill the water tank with clean water.
Open water-tap (note that handle on water-tap should be in line with water-flow).
Ensure that water is flowing freely in the circuit and delivered adequately to both sides of the blade,
as insufficient water supply may result in premature failure of the diamond blade.
In case of frost, empty the water cooling system.