8000m Series
-
47
-
Function
Code
Function
Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
FD.27
12
th
step running
time
0.0~6553s(m)
0.1s(m)
0.0s
○
FD.28
Multi- step
speed 13
-00~100%
0.1%
0.0%
○
FD.29
13
th
step running
time
0.0~6553s(m)
0.1s(m)
0.0s
○
FD.30
Multi- step
speed 14
-100~100%
0.1%
0.0%
○
FD.31
14
th
step running
time
0.0~6553s(m)
0.1s(m)
0.0s
○
FD.32
Multi- step
speed 15
-100~100%
0.1%
0.0%
○
FD.33
15
th
step running
time
0.0~6553s(m)
0.1s(m)
0.0s
○
FD.34
Acceleration
time of 0
th
~7
th
steps
0~0xFFFF
0
○
FD.35
Acceleration
time of 8
th
~15
th
steps
0~0xFFFF
0
○
FD.36
PLC restart
method
0: Restart from 1
st
step
1: Restart from break-off
frequency
0
0
○
FD.37
PLC operation
time unit
0: second (s)
1: minute (m)
0
○
FE Group: Reserved