background image

DUCT KIT ASSEMBLY

9

Installer’s & Owner’s Manual

Step 1.

  Position collar on a flat surface with tabs up.

Step 2.

 Position collar into large hole. Press firmly so that 

tabs of collar go through the plenum hole

Step 3.

 Press down firmly on the sheet metal 

plenum. Lock the collar in position by bending the 
collar tabs outwards and flatten

Step 4. 

All collar tabs are flattened. 

Repeat steps 1 – 4 for top duct assembly.

Optional Accessory: Duct Kit 

Duct Kit Assembly Instructions

Do not drill any pilot holes into the plastic housing. You may damage the internal components. When 
installing screws, be careful not to strip. Lightly tighten screws.

ATTACHING COLLARS

Instructions continued on next page

Summary of Contents for Dry-Boy SDB-45

Page 1: ...SAKURA Basement Air System for Basement Crawlspace Dehumidification Installer s Owner s Manual High Efficiency Dehumidifier Dry Boy Model SDB 45 ...

Page 2: ...btain maximum benefit from your SAKURA Dry Boy dehumidifier Read and Save These Instructions WARNING This symbol means important instructions Failure to heed them can result in serious injury or death CAUTION This symbol means important instructions Failure to heed them can result in injury or material property damage 1 Intended Application SAKURA Dry Boy is intended for installation in crawl spaces...

Page 3: ... but should beinstalled directly in the area to be dehumidified Other considerations include 1 Providing access to a 115 VAC power outlet 10 power cord is provided 2 Locating near a floor or other suitable drain 8 drain hose included 3 Do not install SAKURA Dry Boy with the intake or exhaust of the unit within 1 of a wall or other obstruction Do not place the unit where curtains or debris can be dra...

Page 4: ... RH drops 5 below the set point Approximate Humidity Levels Per Setting Dry 35 to 45 Relative Humidity Normal 45 to 55 Relative Humidity Recommended for most applications Humid 55 to 65 Relative Humidity The dehumidifier will run continuously until the relative humidity RH is reduced to the humidity control dial setting There is no benefit to setting the humidity control to dry in rooms under 65 doi...

Page 5: ...efer to Figure 11 Allow the filter to dry completely before reinstalling Reinstall the filters per the instructions below or on the tag located on the 1 4 pre filter CAUTION NOTE Failure to follow filter handling instructions may result in improper function of the dehumidifier and cause premature filter wear 7 3 Remove Filters 1 Gently remove the 1 4 pre filter by pulling on the tab attached to the filter...

Page 6: ...t breaker tripped 2 Humidity control set to Humid setting 3 Loose connection in internal wiring 4 Humidity control is defective No dehumidification Compressor does not run but blower runs with fan switch AUTO and humidity control turned to ON 1 Defrost thermostat open ambient temperature too low 2 Loose connection in compressor circuit 3 Defective compressor overload 4 Defective compressor or compr...

Page 7: ... Remove middle top cover screw located on the drain port side Do not discard this screw It will be used to attach the mounting bracket in the next step Step 3 Align mounting bracket of condensate pump with the dehumidifier screw hole Reinstall screw that was removed in step 2 Step 4 Remove the 7 hose from the plastic bag and install this hose from the condensate pump onto the adaptor as indicated M...

Page 8: ...8 Installer s Owner s Manual CONDENSATE PUMP INSTALLATION Step 5 Attach the 20 drain hose to the condensate pump and route it to a floor drain Plug in the condensate pump and the assembly is completed ...

Page 9: ... metal plenum Lock the collar in position by bending the collar tabs outwards and flatten Step 4 All collar tabs are flattened Repeat steps 1 4 for top duct assembly Optional Accessory Duct Kit Duct Kit Assembly Instructions Do not drill any pilot holes into the plastic housing You may damage the internal components When installing screws be careful not to strip Lightly tighten screws ATTACHING COLL...

Page 10: ...CT ASSEMBLY 1 Check sealing foam on the top duct assembly Ensure none has come loose 2 Place top duct assembly ensure the sealing foam makes contact around the plastic surfaces 3 Center the top duct assembly ensure the sealing foam makes contact around the plastic surfaces 4 Ensure the rear flange of the top duct assembly is seated flush against the back of the plastic housing See Figure 2 5 DO NOT ...

Reviews: