Smoke ventilator P4
】
Installation guideline
1. Do not install the smoke ventilator in the area with too
many doors or windows to avoid too much Air convection,
otherwise it may not have proper function to remove
smoke.
2. The smoke ventilator must install above the stove.(Fig.
3-2)
3. The machine must be installed horizontally, otherwise the
oil in the oil collector tray (or oil cup) will flow to one side
and overflow.
4. Arrange the distance between the exit of wind pipe and
machine as short as possible, to prevent from
accumulation of air in the pipe and reduce ventilation
effect.
5. The height between the surface of stove and machine
front edge should be 24”~ 32”. (Fig. 3-4)
6. The ventilation exit should not discharge the air toward
other exhaust discharge passage of natural gas or other
fuels.
7. Installed electricity:
(1) The power supply must use regulated Voltage.
(2) Connect earth wire at first and then put on power
supply while installing ventilator. When dismantling the
machine,remove power supply at first, and then
dismantle earth wire.
(3) Do not connect earth wire with water pipe, gas pipe
or phone wire etc. to avoid danger.
4
Too many doors and windows,
Too much Air convection.
(Fig.3-1)
(Fig.3-2)
(Fig.3-3)
(Fig.3-4)
Always horizontal
【
Smoke ventilator P5
】
------------------------------------------------------------------------------------
Installation description
1. Open carton and inspect whether manual, wind pipe
seat ….accessories are there .
2. Connect the power supply and switch on before installation
to check If every function is running normally (motor, lamp).
3. Remove middle frame during the installation of R-602.
Dismantle The screws of middle frame and remove the
middle frame.(Fig. 4-1).Secure with wooden screw upward
through the internal fixed holes of machine onto the
selected location. (Fig.4-2)
4. Please put the machine onto the installation location while
installing R-603.Secure the machine onto the kitchen
cabinet side plate with screws properly in the selected
position of both left and right side of hanging plate. (Fig.
4-4)
5. The machine must be suspended horizontally. (The reason
had been explained in item 3 of Installation guideline)
6. Put the Aluminum pipe to wind pipe seat, extend the
Aluminum pipe to expected length and fixed the wind pipe
seat with 4x12L screws (Attached in the machine) onto the
air exit of machine and another end fixed onto the
ventilation hole. (Fig.4-3)(Fig.4-5)
7. Once the installation is completed, please make sure the
wiring and earth wire connection is done.
4
(Fig.4-1)
(Fig.4-2)
(Fig.4-3)
(Fig.4-4)
(Fig.4-5)