Smoke ventilator P8
】
Trouble shooting
1. Once there is abnormal condition during operation, switch off power and contact nearby
Sakura service station or agent for maintenance.
2. Always switch off power when dealing with abnormal condition.
Problem
Reason and trouble shooting
Tool
Electric
cable
damage
Replace by competence technician out of manufacture or similar
qualification people to avoid danger once there is damage of
cable.
※
Contact nearby Sakura service station or agent for
maintenance.
Cross
screw driver
and long
nose plier
Lamp on
but
motor
stop
A. Dismantle filter wire; rotate the fan with hand to check if it is
stuck. If positive, change motor.
B. If the fan moves freely, then it is the problem of condenser.
1. Check if starting wire (Yellow wire) loose from
condenser.(See wiring diagram)
2. If the wire is OK, then the problem is condenser. Change
condenser.
C. The motor turns a while and stop once you punch the motor
key, and you can smell the burning odor. Then the motor is
malfunction, you have to replace motor.
1/4” wrench
Cross
screw driver
Leaking
oil from
the edge
of
middle
frame
A. Remove the filter wire, check if the sealing between wind pipe
and wind seat were installed properly.
B. Check if there is oil leakage between wind pipe and wind seat;
if positive, try to seal with paint of glue.
Cross
screw driver
Machine
Vibration
A. Check if the motor is secured.
B. If the motor is secured, that means the fan is damage crating
unbalancing vibration. Replace the fan.
1/4” wrench
Cross
screw driver
Poor
suction
A. The space between smoke ventilator and stove is too high.
B. Too many door/ window around ventilator that created air
convection.
C. If the ventilator is installed on the window, it is better to add a
wooden board under the rear bottom of ventilator and align
with the rear part of ventilator to hide the space of window.
D. Install the machine according to Installation guideline.
Slant
machine
A. In case of right/left slant, adjust with hanging steel to level the
height.
B. In case it is prone to front side, screw in the wooden bolt again
(suspended 0.5~10 cm outside of wall), or check if the screw
tightened to machine is loosed.
Cross
screw driver
Change
lamp
R-602 Loosen the screws on the lamp panel with cross screw
driver to remove the panel, then rotate the 40 W bulb out,
replace with a new bulb.
R-603 Loosen the screws on the lamp panel with cross screw
driver to remove the panel, then rotate the 13 W PL bulb
out, replace with a new bulb.
Cross
screw driver
9
【
Smoke ventilator P9
】
------------------------------------------------------------------------------------
R-602 Circuit diagram, function
Function
Setting Voltage ~ frequency
120 V / 60 Hz
Transmission method
Single motor
Wind pipe diameter
150
Illumination
Max. 40 W lamp
Speeds
High (2) Low (1)
RPM
1600 RPM, 1400 RPM
Discharge volume ( exit )
8.1 m
3
/ min. , 5.2 m
3
/ min.
Motor power consumption
90w
10
Circuit Diagram
Condenser
Moter
b
ro
w
n
b
lu
e
y
e
llo
w
w
h
ite
g
ra
y
blue
yellow
brown
blue
black
brown
white
black
Lamp
Earth wire
POWER
SUPPLY
120V 60Hz