background image

------------------------------------------------------------------------------------

Smoke ventilator      P8

 

 

Trouble shooting 

 
1. Once there is abnormal condition during operation, switch off power and contact nearby 

Sakura service station or agent for maintenance. 

2. Always switch off power when dealing with abnormal condition. 

Problem 

Reason and trouble shooting 

Tool 

Electric 

cable 

damage 

Replace by competence technician out of manufacture or similar 
qualification  people  to  avoid  danger  once  there  is  damage  of 
cable. 

Contact  nearby  Sakura  service  station  or  agent  for 

maintenance. 

Cross 

screw driver 

and long 

nose plier 

Lamp on 

but 

motor 

stop 

A.  Dismantle filter wire; rotate the fan with hand to check if it is 

stuck. If positive, change motor. 

B.  If the fan moves freely, then it is the problem of condenser. 

1.  Check  if  starting  wire  (Yellow  wire)  loose  from 

condenser.(See wiring diagram) 

2.  If the wire is OK, then the problem is condenser. Change 

condenser. 

C.  The motor turns a while and stop once you punch the motor 

key,  and  you  can  smell  the  burning  odor.  Then  the  motor  is 
malfunction, you have to replace motor. 

1/4” wrench 

Cross 

screw driver 

Leaking 

oil from 

the edge 

of 

middle 

frame 

A.  Remove the filter wire, check if the sealing between wind pipe 

and wind seat were installed properly. 

B.  Check if there is oil leakage between wind pipe and wind seat; 

if positive, try to seal with paint of glue.   

Cross 

screw driver 

Machine 

Vibration 

A.  Check if the motor is secured. 
B.  If the motor is secured, that means the fan is damage crating 

unbalancing vibration. Replace the fan. 

1/4” wrench 

Cross 

screw driver 

Poor 

suction 

A.  The space between smoke ventilator and stove is too high. 
B.  Too  many  door/  window  around  ventilator  that  created  air 

convection. 

C.  If the ventilator is installed on the window, it is better to add a 

wooden  board  under  the  rear  bottom  of  ventilator  and  align 
with the rear part of ventilator to hide the space of window. 

D.  Install the machine according to Installation guideline.   

 

Slant 

machine 

A.  In case of right/left slant, adjust with hanging steel to level the 

height. 

B.  In case it is prone to front side, screw in the wooden bolt again 

(suspended 0.5~10 cm outside of wall), or check if the screw 
tightened to machine is loosed.   

Cross 

screw driver 

Change 

lamp 

R-602  Loosen  the  screws  on  the  lamp  panel  with  cross  screw 

driver to remove the panel, then rotate the 40 W bulb out, 
replace with a new bulb. 

R-603  Loosen  the  screws  on  the  lamp  panel  with  cross  screw 

driver to remove the panel, then rotate the 13 W    PL bulb 
out, replace with a new bulb. 

Cross 

screw driver 

 

Smoke ventilator      P9

------------------------------------------------------------------------------------ 

 

R-602 Circuit diagram, function     

 

 

 

Function 

Setting Voltage ~ frequency 

120 V / 60 Hz 

Transmission method 

Single motor 

Wind pipe diameter 

150 

Illumination 

Max. 40 W lamp 

Speeds 

High (2) Low (1) 

RPM 

1600 RPM, 1400 RPM 

Discharge volume ( exit ) 

8.1 m

3

 / min. , 5.2 m

3

 / min. 

Motor power consumption 

90w 

10 

Circuit Diagram

Condenser 

Moter 

b

ro

w

n

b

lu

e

y

e

llo

w

w

h

ite

g

ra

y

blue

yellow 

brown 

blue

black 

brown 

white

black 

Lamp 

Earth wire 

POWER 

SUPPLY 

120V 60Hz 

Reviews: