12-34-0000 RELAY OUTPUT EXPANSION MODULE 

 

Product Manual 

 

 

 

Sea Air and land Communications Ltd, 10 Vanadium Place, Addington, Christchurch 8024, New Zealand 

 

 April 2018 

Installation and Connections 

 

 

The power supply is connected via the green power connector to +13.8 Volts and Ground. The 
supply input is protected against reversed connection. 

 

Figure 1. Pin numbering:  Looking into the sockets, pin 1 is on the left 

S1 

 Serial Port One 

 

S2 - Serial Port Two 

Pin 

Description 

 

Pin 

Description 

Ground 

 

Ground 

Not Used 

 

Not Used 

Not Used 

 

Not Used 

Not Used 

 

Not Used 

RS232 Rx 

 

RS232 Tx 

RS232 Tx 

 

RS232 Rx 

 

 

Figure 2. Pin outputs for relay connectors. 

Summary of Contents for 12-34-0000

Page 1: ...Copyright 2017 Sea Air and Land Communications Ltd All rights reserved 12 34 0000 Relay Output Expansion Module PRODUCT MANUAL Version 1 02 April 2018...

Page 2: ...cumentation This document is designed to familiarise you with Salcom products and guide you through the hardware configuration installation and overall system management Salcom is an environmentally c...

Page 3: ...pre paid Please include a description of the fault to assist with prompt return Any unauthorised alterations or repairs will invalidate the warranty All information provided in this document is caref...

Page 4: ...A green and red LED display operational status a chart displaying status codes can be found in section 4 Connections A 12 terminal connector is used to bring all connections from the 4 relays out The...

Page 5: ...ted via the green power connector to 13 8 Volts and Ground The supply input is protected against reversed connection Figure 1 Pin numbering Looking into the sockets pin 1 is on the left S1 Serial Port...

Page 6: ...he use of configuration software it can be set from a terminal 9600 N 8 1 Configurable items are Monoshot time for each relay Unit ID On startup the 12 34 will respond with SALCOM 12 34 0000 Unit ID X...

Page 7: ...n Christchurch 8024 New Zealand April 2018 2 To set Relay 2 monoshot time 3 To set Relay 3 monoshot time 4 To set Relay 4 monoshot time 5 To set unit ID When setting relay times the 12 34 will respond...

Page 8: ...F Valid command received but wrong ID ON at least one second ON at least one second Valid command received for this unit Slow Flashing Fast Flashing Error Condition Relay Operation Relays are controll...

Page 9: ...gton Christchurch 8024 New Zealand April 2018 e g 23109 Will only address a unit with matching ID 23 Relay 1 will be closed No other action taken 231209 Will close relay 1 and 2 on a unit with the ID...

Page 10: ...ODULE Product Manual Sea Air and land Communications Ltd 10 Vanadium Place Addington Christchurch 8024 New Zealand April 2018 Multiple Unit Set Up Figure 4 Multiple units controlled by a 12 84 receive...

Page 11: ...S232 Discrete Outputs 4 Relay Contacts 1A 24VDc Note Not suitable for 240VAC Connections Connectors Serial Port 1 RS232 RJ12 6P6C Serial Port 2 RS232 RJ12 6P6C Relay Outputs 4 off 12 way plug socket s...

Page 12: ...r and land Communications Ltd 10 Vanadium Place Addington Christchurch 8024 New Zealand April 2018 How to Contact Us Sea Air and Land Communications Salcom Ltd 10 Vanadium Place Addington Christchurch...