EKS (NI, NIS, NV, NV PH, NV PTC/PS)

www.salda.lt

EKS duct heaters are designed to heat clean air in ventilation systems and to preheat air handling units. 

Corrosion resistant casing

 with excellent 

thermal reflectivity is made from AluZinc. Duct connection is with rolled rubber seals, duct heater elements are made from stainless steel. To ensure 

safety in duct heaters are installed 

2 protection thermostats

 and screw terminals for easy connection.

To ensure long service time of heaters, 

casings are produced from AluZinc

 coated steel and heating elements from stainless steel AISI 304. AluZinc 

for heaters casing was selected for it’s properties:

• Good corrosion resistance at high temperatures (up to 315 °C) 

• Excellent thermal reflectivity 

• Good abrasion resistance because of its surface hardness 

• 

Durability:

 under normal conditions the AZ 150 coating grade will protect the steel substrate from corrosion for a minimum period of 

15 years

.

To ensure security in case of fire in all electric air heaters are installed 2 heat protection thermostats:

• 

First overheat protection

 automatically 

activates

 if temperature reaches 

50°C

, then protection disconnects heating elements, 

until it has cooled. When the temperature falls to the working temperature, heater 

automatically

 switches on. 

• 

Second overheat protection

 automatically 

activates

 if temperature reaches 

100°C

, then protection disconnects heating ele-

ments, until it has cooled. In this case need to figure the cause of the overheating of the heater. Heater needs to be reset 

manually 

with the pushbutton on the heaters casing.

For easy duct connection heaters casing is with rolled rubber seals.

EKS NV PTC/PS, EKS NV PH (3X400V)

C – heating element

S1 - Automatic circuit 

breaker

B - protection from overheat-

ing 50°C (automatic),

A - protection from overheat-

ing 100°C (manually), 

J - Switch

K1..K5 - Contactor

PS – pressure relay

PTC  - air flow sensor

V1, V2 – Triac

EKR-KN – Control board

TR 5 – external potentiom

-

eter

TJK10K – Temperature 

sensor

X3...X26 – the control board 

contacts (see. on PCB)

Summary of Contents for EKS

Page 1: ...Subject to technical modification EKS_P0082_AZ_0002 ELECTRIC DUCT HEATERS EKS EKS NI EKS NIS EKS NV EKS NV PH EKS NV PTC PS USER MANUAL...

Page 2: ...NSTALATION 4 Electrical connection 4 WIRING DIAGRAMS 5 HEATERS DESCRIPTION STRUCTURE 6 Double overheat protection 6 Duct connection 6 CONTROL 7 External control of three phase heaters 7 External contr...

Page 3: ...dry place with humidity not more 70 20 C average ambient temperature must be 5 40 C Storing place must be covered from water and dirt Avoid long term storing It is not recommended to store products m...

Page 4: ...air filter before the heater AHU air handling unit with heat recovery F filter for supply air Depending on the installation location of the heater in the duct relative to the engine before or behind...

Page 5: ...Control board TR 5 external potentiom eter TJK10K Temperature sensor X3 X26 the control board contacts see on PCB EKS NV EKS NI EKS NIS 3x400V I V heater steps B protection from overheat ing 50 C auto...

Page 6: ...r a minimum period of 15 years To ensure security in case of fire in all electric air heaters are installed 2 heat protection thermostats First overheat protection automatically activates if temperatu...

Page 7: ...u can set temperature from distance with wired remote potentiometer TR5K Type NIS heater control from distance with 0 10V signal Type PTC heater with installed air flow sensor Type PS heater with inst...

Page 8: ...NI NIS NV NV PTC PS NV PH 800x500 WxH Length L mm 370 420 440 500 Power kW 9 12 15 18 21 24 27 30 33 36 39 42 45 51 54 60 66 EKS NI NIS NV NV PTC PS NV PH 1000x500 WxH Length L mm 370 420 440 500 Powe...

Page 9: ...3 x 400 3 x 230 Power kW 18 0 9 9 30 0 15 15 54 0 15 9 12 18 18 0 9 9 30 0 9 9 12 54 0 9 12 15 18 EKS NIS 1200x550 WxH Length L mm 370 440 370 440 Voltage V 50Hz 3 x 400 3 x 230 Power kW 21 0 12 9 36...

Page 10: ...kers data it must correspond to heaters electrical data 2 Check isolation of connection cables wires check is heater grounded 3 Check power supply source data it must correspond to heaters elec trical...

Page 11: ...11 EKS NI NIS NV NV PH NV PTC PS www salda lt...

Page 12: ...tos descriptions and etc has to be sent with this form Photos must be taken in such a way that product or product part label and possible defect part is clearly visible and identified Warranty claim w...

Reviews: