BRINE-WATER HEAT PUMPS

INSTALLATION AND MAINTENANCE MANUAL

Summary of Contents for SIG 6-17

Page 1: ...Subject to technical modi cation SIG 6 17 BRINE WATER HEAT PUMPS INSTALLATION AND MAINTENANCE MANUAL...

Page 2: ...information 6 4 1 1 Place for instalation 6 4 1 2 Acoustic Emissions 6 4 2 HeatingSystemConnetion 6 4 3 Heat Source Connection 7 4 3 1 Filling and venting the collector system 8 4 4 Electrical Probes...

Page 3: ...directive and is thus subject to the requirements of EC directive 2006 95 EC low voltage directive It is thus also intended for use by non professionals for heating shops of ces and other similar work...

Page 4: ...ed exclusively for the heating of heating water It can be used in new or previously existing heating systems Brine is used as the heat transfer medium in the heat source system Borehole heat exchanger...

Page 5: ...or procedure of each task itself Insert forks lengthwise under the wooden pallet When lifting make sure the weight is equally distributed Never tilt the heat pump beyond max 45 in any direction when...

Page 6: ...h the heating system prior to connecting the heat pump Before connecting the heating water system to the heat pump the heating system must be ushed to remove any impurities residue from sealants etc A...

Page 7: ...ting the heat source Connect the brine pipe to the heat pump ow and return The hydraulic plumbing diagram must be adhered to ATTENTION The dirt trap must be inserted in the heat source inlet of the he...

Page 8: ...either direction depending upon phasing of the power There is a 50 50 chance of connecting power incorrectly in such a way to cause rotation in the reverse direction and damage compressor To avoid thi...

Page 9: ...th a contact gap of at least 3 mm e g utility blocking contactor or power contactor as well as a 1 pole circuit breaker have to be provided by the customer The required conductor cross section is to b...

Page 10: ...ng on the type of heat pump us age so that the most unfavourable operating state with respect to the water ow rate is achieved This normally means the heating circuits of the rooms on the south and we...

Page 11: ...e frequently a 5 formic acid solution should be used In either case the cleaning uid should be at room temperature We recommend ushing the heat exchanger in the direction opposite to the normal ow dir...

Page 12: ...3 76 Min brine ow m h 0 63 0 86 1 1 1 27 1 57 1 8 Pressure loss 3 0 K t with B0 35 kPa 8 7 7 8 9 9 Residual pressure with 3 0 K t with B0 35 kPa 31 41 44 40 60 57 Heating medium Water Heating medium...

Page 13: ...13 SIG 6 17 www salda lt Pic 10 1 Outside temperature sensor Temperature sensor...

Page 14: ...ating Tout 35 C Heating Tout 50 C Brine in C Power kW 6 4 2 0 2 4 6 8 10 12 1 1 5 2 Power consumption Heating Tout 35 C Heating Tout 50 C Brine in C Power kW 6 4 2 0 2 4 6 8 10 12 2 3 4 5 6 Coefficien...

Page 15: ...Heating Tout 35 C Heating Tout 50 C Brine in C Power kW 6 4 2 0 2 4 6 8 10 12 1 1 5 2 2 5 Power consumption Heating Tout 35 C Heating Tout 50 C Brine in C Power kW 6 4 2 0 2 4 6 8 10 12 2 3 4 5 6 7 Co...

Page 16: ...ting Tout 35 C Heating Tout 50 C Brine in C Power kW 6 4 2 0 2 4 6 8 10 12 1 1 5 2 2 5 3 3 5 Power consumption Heating Tout 35 C Heating Tout 50 C Brine in C Power kW 6 4 2 0 2 4 6 8 10 12 2 3 4 5 6 7...

Page 17: ...g Tout 35 C Heating Tout 50 C Brine in C Power kW 6 4 2 0 2 4 6 8 10 12 1 1 5 2 2 5 3 3 5 4 Power consumption Heating Tout 35 C Heating Tout 50 C Brine in C Power kW 6 4 2 0 2 4 6 8 10 12 2 3 4 5 6 7...

Page 18: ...ing Tout 35 C Heating Tout 50 C Brine in C Power kW 6 4 2 0 2 4 6 8 10 12 2 2 5 3 3 5 4 4 5 Power consumption Heating Tout 35 C Heating Tout 50 C Brine in C Power kW 6 4 2 0 2 4 6 8 10 12 2 3 4 5 6 7...

Page 19: ...Heating Tout 35 C Heating Tout 50 C Brine in C COP 6 4 2 0 2 4 6 8 10 12 10 12 14 16 18 20 22 24 Heating capacity Heating Tout 35 C Heating Tout 50 C Brine in C Power kW 6 4 2 0 2 4 6 8 10 12 2 3 4 5...

Page 20: ...20 SIG 6 17 www salda lt Pic 10 4 1...

Page 21: ...21 SIG 6 17 www salda lt Pic 10 4 2...

Page 22: ...22 SIG 6 17 www salda lt Pic 10 4 3...

Page 23: ...l relay NS2 25k 9 14A 1 Q1 Aux contact NS2 AE11 1 FR phase sequence relay RM4 TG20 1 TR1 Transformers 230VAC 24VDC 1 R1 R6 Relay RT424730 witk sock et RT78726 andRT17017 230V AC 6 RG1 Controller PCO3m...

Page 24: ...24 SIG 6 17 www salda lt Pic 10 5 1 Pic 10 5 2 Domestic hot water Direct Heating system...

Page 25: ...6 17 www salda lt Pic 10 5 3 Pic 10 5 4 Heating system with buffer tank or hydraulic separator and circulation pump Heating system with buffer tank or hydraulic separator mixing valve and circulation...

Page 26: ...26 SIG 6 17 www salda lt Pic 10 5 5 Pic 10 5 6 Domestic hot water and Heating systems Domestic hot water and Heating systems with buffer tank or hydraulic separator and circulation pump...

Page 27: ...27 SIG 6 17 www salda lt Pic 10 5 7 Domestic hot water and Heating systems with buffer tank or hydraulic separator mixing valve and circulation pump...

Page 28: ...IG 14 SIG 17 EC Directives EC Low Voltage Directive 73 23 EEC EC EMC Directive 89 336 EEC is in compliance with the requirements of a Government Regulation No 9 2002 17 2003 18 2003 163 2002 and 312 2...

Page 29: ...29 SIG 6 17 www salda lt...