11
QUICK GUIDE
EQUINOX
- SOLAR INVERTERS
Connecting the network cables:
1.
Unscrew the AC connector (supplied) and prepare the cables coming from the junction box of the power supply:
2.
Pass the cables through the screw cap, crown and rubber seal, as shown below. To optimise the connection, we recommend
crimping the terminals at the ends of the cables.
3.
Insert and screw the cables to the corresponding terminals on the connector: R phase, S phase, T phase and earth (G). Once this is
done, pull gently on the cables to make sure they are firmly attached.
4.
Connect the sleeve to the inverter’s AC connector.
5.
Connect the other end of the sleeve to the AC protection in the junction box.
6.
Connect the AC part of the junction box downstream of the main automatic circuit breaker for the power supply.
ICP
Automatic
circuit breaker
ID
PIAs