26
MODEL
SLC-700-TWIN
SLC-1000-TWIN
SLC-1500-TWIN
SLC-2000-TWIN
SLC-3000-TWIN
BATTERIES
Type
AGM sealed, 3-5 years
Quantity
3, 7Ah
8, 7Ah
GENERALS
Type
On-line double conversion
Communication ports
RS-232 + AS400 (option)
Software
WinPower
Noise level at 1m.
< 55 dB
50 dB
Operating temperature
0ºC ÷ +40ºC
Storage temperature
- 20ºC ÷ +70ºC, without batteries
Relative humidity
To 95%, non-condensing
Operating altitude
1000 m.a.s.l.
Protection degree
IP20
Dimensions (D x W x h) Tower
410 x 145 x 220 mm.
470 x 195 x 347 mm.
Rack 19”
450 x 483 x 2U
450 x 483 x 2U (x2)
Weight Tower
13 kg. / 6 kg. (B1)
14 kg. / 7 kg. (B1)
30 kg. / 14 kg. (B1)
31 kg. / 15 kg. (B1)
32 kg. / 16 kg. (B1)
Rack 19”
16 kg. / 8 kg. (B1)
17 kg. / 9 kg. (B1)
10+28 kg. / 10 kg. (B1)
11+28 kg. / 11 kg. (B1)
12+28 kg. / 12 kg. (B1)
Safety
IEC/EN 62040-1-1 (220V equipments); UL1778 (110V equipments)
Electromagnetic compatibility
(EMC)
IEC/EN62040-2, Category C1 (220V equipments); FCC PART 15 Class B (110V equipments)
Operating
EN 62040-3
Quality system
ISO 9001 and ISO 14001 TÜV
Table 10.
Technical specifications table
i
If the UPS is installed in an altitude higher than 1000 metres,
the output power rate will be derated according to the fol-
lowing table:
Altitude (m)
1000
1500
2000
2500
3000
3500
4000
4500
5000
Max. power (%)
100
95
91
86
82
78
74
70
67
Table 11.
Output power derate according to the operating altitude.
7.2.
GLOSSARY.
•AC
It is nominated as alternating current (CA in
Spanish abbreviation and AC in English) to the
electrical current in which the magnitude and di-
rection varies in a cyclic way. The most common
wave shape of the alternating current is sinewave,
because the energy transmission is better. Nev-
ertheless, some applications could need other
period wave shapes, like triangular or square.
•Boost
Direct converter of DC that supplies an output
voltage higher than its input.
•Bypass
Manual or automatic, it is the physical junction
between the input and the output of an elec-
trical device.
•DC and AC
The direct current (CC in Spanish, DC in English)
is the continuous electron flow through a cable
between two points with different potential.
Unlike the alternating current (CA in Spanish,
AC in English), in direct current the electrical
charge always flow in the same direction from
the highest potential point to the lowest one.
Although, usually the direct current is identified
with the constant current (for example the one
supplied by the battery), it is direct current any
current that always maintain its polarity.
•EMI filter
Filter, which is able to reduce the electromag-
netic interference considerably. EMi is the per-
turbation that occurs in a radio transmission or
any other electrical circuit caused by an electro-