diodes, whether solid state semiconductors, vacuum valves 

or gaseous valves, such as those containing mercury va-

pour. depending on the characteristics of the AC power that 

they use, they are classified as single-phase when they are 

powered by a mains phase or three-phase when they are 

powered by three phases. depending on the type of recti-

fication, they can be half wave when only one of the half 

cycles of the current is used or full wave when both half 

cycles are used.

 

Relay.-

 A relay is an electromechanical device that func-

tions as a switch controlled by an electrical circuit in which, 

by means of an electromagnet, a set of one or several con-

tacts is activated to enable other independent electrical 

circuits to be opened or closed.

 

SCR.-

 Silicon controlled rectifier, commonly known as a 

thyristor, a 4-layer semiconductor device that works as an 

almost ideal switch.

 

ThD.-

 Total harmonic distortion. harmonic distortion oc-

curs when the output signal of a system does not equal 

the signal that entered it. This lack of linearity affects the 

waveform because the device has introduced harmonics 

that were not in the input signal. Since they are harmonic, 

that is to say, multiples of the input signal, this distortion is 

not so dissonant and is less easy to detect.

SPS ADVANCE R & T

 UnInTeRRUPTIbLe PoweR SUPPLy (UPS)

USER MANUAL        

Summary of Contents for SPS 750 ADV R

Page 1: ...SPS ADVANCE R T 0 75 1 5 kVA 0 85 3 kVA UNINTERRUPTIBLE POWER SUPPLY SYSTEMS UPS USER MANUAL...

Page 2: ...2 SALICRU...

Page 3: ...ions 5 2 1 Connection of the input 5 2 2 Connection of the IEC output connectors 5 2 3 Output terminals only in SPS ADVANCE T 3 KVA models 5 2 4 Connection to the optional battery module backup extens...

Page 4: ...ed personnel Although no effort has been spared to ensure that the in formation in this user manual is complete and accurate we are not responsible for any errors or omissions that may exist The image...

Page 5: ...alled and operating it is rec ommended to save the documentation downloaded from the website CD ROM or Pen Drive in a safe and easy to access place for any future queries or doubts that may arise The...

Page 6: ...ccess areas EN IEC 60950 1 Information technology equipment Safety Part 1 General requirements EN IEC 62040 2 Uninterruptible Power Supplies UPS Part 2 EMC requirements The manufacturer is not liable...

Page 7: ...revail The nameplate of the device shows all of the values relating to its main properties and characteristics Act accordingly for its installation 4 1 1 1 Views of the SPS ADVANCE R device Control pa...

Page 8: ...0 VA models Control panel with LCD display Plastic front trim Front view of the device Batteries modules for 1000 to 2000 VA models Plastic front trim Front view of the batteries modules Battery modul...

Page 9: ...ector Rear view of the B1 device Fig 4 Rear views of devices according to power 3000 VA model Fans IEC AC output sockets Smart slot protective cover RS232 COM port For connection to external EPO AC po...

Page 10: ...extra charger and batteries external to the UPS ADV R Rack format device series ADV T Tower format device series 1000 Power in VA SPS Acronym for interactive UPS Standby Power Systems EE Special custo...

Page 11: ...s communications directly with a server and the protocol is in accordance with an RS232 interface SPS ADVANCE T models also have an additional USB serial port for communication and control of the devi...

Page 12: ...l conditions of the whole system device supply voltage and or load voltage characteristics or their type etc In any event it will always be supplied as a peripheral compo nent external to the device i...

Page 13: ...ty registration 1 RS232 cable 1 USB cable only in SPS ADVANCE T models 1 cable for the device s AC power supply 2 metal pieces for use as handles and screws for installing the unit in a rack cabinet o...

Page 14: ...they will be at least the current indicated on the nameplate of the UPS Only the rated current as indicated by the EN IEC 62040 1 safety standard is printed on the nameplate of the device For the calc...

Page 15: ...ect a device to an optional battery module or bet ween modules or to install an optional card in the slot it is necessary to remove its respective metal protective cover screwed to the UPS Remove the...

Page 16: ...for the installation of an ex ternal emergency power off EPO output button The device is dispatched from the factory with its EPO cir cuit set to closed NC by default In other words the UPS will cut t...

Page 17: ...quired software and install it Directly through the Website Enter the following in the browser s address bar https www salicru com Click the Enter key The page shows two sections on the screen Search...

Page 18: ...Start the load or loads making sure that the rated power of the device is not exceeded In the ADVANCE T the fan or fans according to the model will be put into operation depending on the of load con n...

Page 19: ...oad Information on battery operation cut in supply Information on device faults Audible alarm unmute Fig 12 Graphic and textual information shown on the display Button Description ON OFF Starting up t...

Page 20: ...t V X X V V V V Press 3 sec disable audible warning V X X V Repeat press 3 sec enable audible warning V X X X Overload and fault alarm V X V Error code Other alarms and faults X X V Error code Tab 7 O...

Page 21: ...g Low battery Beep every 2 s No Overload Beep every 0 5 s Fault Fault Continuous No Tab 10 Audible alarms 7 4 Warning and error or fault codes Code Description of the warning A56 Low battery voltage w...

Page 22: ...m No other person should handle them 8 2 UPS troubleshooting guide If the UPS does not work properly check the information shown on the LCD screen of the control panel and act accordingly de pending o...

Page 23: ...rmal mode E15 Unbalanced loads Turn off UPS Check device s loads E18 Fan fault Contact distributor seller or failing that our T S S E19 Overtemperature Turn off UPS Turn on again and check that fan is...

Page 24: ...ble alarm and fault after 1 min 120 10 Immediate fault Batteries AGM sealed 3 5 years life Element voltage 6 V DC Capacity 9 Ah 7 Ah 9 Ah Number of batteries in device connected in series group voltag...

Page 25: ...t Overload in battery mode 110 10 Audible alarm and fault after 1 min 120 10 Immediate fault Batteries AGM sealed 3 5 years life Only devices other than B1 Element voltage 12 V DC Capacity 7 Ah 7 2 Ah...

Page 26: ...h is the disturbance that occurs in a radio receiver or in any other electrical circuit caused by electromagnetic radiation coming from an ex ternal source Electromagnetic interference is also known a...

Page 27: ...an electrical circuit in which by means of an electromagnet a set of one or several con tacts is activated to enable other independent electrical circuits to be opened or closed SCR Silicon controlled...

Page 28: ...ompany salicru salicru_SA Product Range Uninterruptible Power Supplies UPS Lighting Flow Dimmer Stabilisers DC Power Systems Static Inverters Photovoltaic Inverters Voltage stabilisers TheTechnicalSer...

Reviews: