background image

6

SALICRU

3.  QUALITY ASSURANcE ANd STANdARdS.

3.1.  sTaTemenT by The managemenT.

our goal is customer satisfaction, therefore this management 

has decided to establish a Quality and environment Policy, 

through the implementation of a Quality and environmental 

management System that will enable us to comply with the 

requirements demanded in the 

ISO 9001

 and 

ISO 14001

 and 

also by our Customers and Stakeholders.

Likewise, the management of the company is committed to 

the development and improvement of the Quality and environ-

mental management System, through:

 

Communication to the entire company of the importance of 

satisfying both the client's requirements as well as legal 

and regulatory requirements.

 

The dissemination of the Quality and environment Policy 

and the setting of the Quality and environment objectives.

 

Conducting reviews by the management.

 

Providing the necessary resources.

3.2.  sTandards.

SPS home is designed, manufactured and sold in accordance 

with Quality management Standard

EN ISO 9001

. The mark 

 indicates conformity to the eeC directives through the ap-

plication of the following standards:

 

2014/35/EU

. - Low voltage safety.

 

2014/30/EU

. - electromagnetic Compatibility (emC).

 

2011/65/EU

.  - Restriction of the use of hazardous sub-

stances in electrical and electronic equipment (RohS).

According to the specifications of the harmonized standards. 

Reference standards:

 

EN-IEc 62040-1

. Uninterruptible power supplies (UPS). 

Part 1-1: general and safety requirements for UPS used in 

user access areas.

 

EN-IEc 60950-1

. Information technology equipment. 

Safety. Part 1: general requirements.

 

EN-IEc 62040-2

. Uninterruptible power supplies (UPS). 

Part 2: emC requirements.

 The manufacturer accepts no liability in the event of 

modification of or intervention on the device by the 

user.

 

WARNING!:

 

 The SPS.home is a category C1 UPS.

It is not appropriate to use this device with basic life 

support applications, where a failure of the former can 

render vital equipment out of service or significantly 

affect its safety or effectiveness. It is also not recom-

mended in medical applications, commercial transport, 

nuclear installations, or other applications or loads, 

where a failure of the product can lead to personal or 

material damages.

 The eC declaration of conformity of the product is avail-

able to the customer upon express request to our head-

quarters.

3.3.  environmenT.

This product has been designed to respect the environment and 

manufactured according to 

ISO 14001

.

Recycling of the equipment at the end of its useful life:

our company undertakes to use the services of authorized and 

regulatory companies to treat the set of products recovered at 

the end of their useful life (contact your distributor).

Packaging:

for the recycling of the packaging there must be compliance 

with the legal requirements in force, according to the specific 

regulations of the country where the equipment is installed.

Batteries:

batteries pose a serious danger to health and the environment. 

The disposal of them shall be carried out in accordance with 

the laws in force.

Summary of Contents for SPS.HOME

Page 1: ...SPS HOME USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS...

Page 2: ...2 SALICRU...

Page 3: ...ntents 5 2 Siting and considerations 5 2 1 Siting 5 2 2 Considerations 5 2 2 1 Battery charging 5 2 2 2 Power connected to the SPS HOME 5 3 Connection and commissioning 5 3 1 Procedure to follow 5 3 1...

Page 4: ...by qualified personnel Although no effort has been spared to ensure that the in formation in this user manual is complete and accurate we are not responsible for any errors or omissions that may exist...

Page 5: ...for the correct identification of each of the parts which together with the in structions described in this user manual allows the operations of installation and commissioning to be performed in a sim...

Page 6: ...UPS Part 1 1 General and safety requirements for UPS used in user access areas EN IEC 60950 1 Information technology equipment Safety Part 1 General requirements EN IEC 62040 2 Uninterruptible power s...

Page 7: ...perform this task of protection against mains failures by providing a similar voltage for a period of time Under normal conditions the output of the UPS is the same as the input of the AC power mains...

Page 8: ...will charge irrespective of whether the SPS HOME is switched on or off 5 2 2 2 Power connected to the SPS HOME Check that the loads connected to the power sockets do not exceed the power rating of th...

Page 9: ...ted beep every 0 5 sec for moderate overload or continuous for excessive Normal Tripped Overload Activated by excessive load connected to the device s output sockets Stop the UPS disconnect the load A...

Page 10: ...o load connected to prevent a mains failure from discharging the battery and leaving the loads unpowered Unit has been damaged by a repetition of voltage peaks Contact distributor or seller and failin...

Page 11: ...er surges Battery Element rated voltage 12 V DC Pb Ca sealed maintenance free battery Number of elements Capacity 1 5 Ah 1 5 6 Ah Typical recharge time 8 hours to 90 charge Optical and audible indicat...

Page 12: ...alicru_SA Product Range Uninterruptible Power Supplies UPS Lighting Flow Dimmer Stabilisers DC Power Systems Static Inverters Photovoltaic Inverters Voltage stabilisers Variable frequency drives The T...