5.  INSTALLATION ANd OPERATION.

 

Read and respect the Safety Information, described 

in chapter 2 of this document. failure to obey some 

of the instructions described in this manual can result in a 

serious or very serious accident to persons in direct contact 

or in the vicinity, as well as faults in the equipment and/or 

loads connected to it.

5.1.  recePTion of The device.

5.1.1.  reception, unpacking and contents.

 

Reception.

 

ˆ

Check that the information on the label affixed to the 

packaging matches that specified on the order. Re-

move the packing unit and check the above information 

against that on the nameplate of the SPS.home.

If there are any discrepancies, report them, quoting the 

references on the delivery note.

 

ˆ

Check that no mishaps have occurred during transpor-

tation.

 

Unpacking.

 

ˆ

The packaging consists of a full-colour cardboard box 

with two moulded pieces of expanded polystyrene 

(ePS) to protect the SPS.home from impacts.

 

Content.

 

ˆ

device.

 

ˆ

Quick guide.

 

ˆ

warranty information.

 

ˆ

Particular terms and conditions of warranty.

 

ˆ

1 USb cable.

 

ˆ

1 telephone/ASdL/modem cable.

 

After reception, it is advisable to store the device in its 

original packaging as a preventative measure if installation 

is not to be carried out immediately.

 

when the packaging needs to be disposed of, it must be 

carried out in accordance with current laws.

we advise keeping it for at least 1 year.

5.2.  siTing and consideraTions.

5.2.1.  siting.

 

Install the unit in a location which takes into considera-

tion and complies with the Safety Instructions of document 

ek266*08.

 

The UPS can be placed on a flat surface (on a table) or 

mounted on a wall using the system located on the base 

of the device.

5.2.2.  considerations.

5.2.2.1.  battery charging.

 

Although the unit’s internal battery is charged at the factory, 

it may run down during transportation and/or storage, so it 

should be charged for a minimum of 8 hours to ensure a full 

charge before using the device with complete assurance.

Although the device can operate correctly without charging 

the battery for the specified time, the risk of a prolonged 

mains outage during the first hours of operation and the 

UPS’s available backup time should be assessed.

 

To recharge the battery, simply leave the unit plugged 

into an AC socket. The battery will charge irrespective of 

whether the SPS.home is switched on or off.

5.2.2.2.  Power connected to the SPS.home.

 

Check that the loads connected to the power sockets do 

not exceed the power rating of the unit (see Section 7 of 

this document).

If the rated capacities are exceeded, an overload condi-

tion will occur. If mains power is present, the input breaker 

will trip and, in battery mode, the device’s inverter will be 

blocked. either way, the end result will be an unwanted 

stoppage of the device and loads.

 

for optimum performance, keep the load connected to the 

SPS below 80% of rated capacity.

5.3.  connecTion and commissioning.

 

All of the device’s connections, including those re-

lated to control, will be made with all of the 

switches in standby and without mains power present (UPS 

power supply line selector set to ‘off’).

 

It should never be forgotten that a UPS is a gener-

ator of electrical energy, so the user must take the 

necessary precautions against direct or indirect contact 

when it is part of the facility.

5.3.1.  Procedure to follow.

observe the following order of operation and instructions:

1. 

Plug the PC, screen and sensitive devices into the unit’s output 

sockets 

3

. Plug the modem and other non-sensitive and 

low-consumption peripherals into the SPS.home’s output 

sockets 

4

.

do not plug

 laser printers, paper shredders or other 

high-consumption electrical devices or high current 

probes into output sockets 

4

 and especially not into output 

sockets 

3

 with backup. The power demand of any of these 

devices will overload the SPS and possibly damage the 

unit.

2. 

Take power cable 

1

 and insert the plug into a properly con-

nected AC socket with an earth connection.

The socket that supplies power to the device must have a 

properly connected earth cable 

(

)

.

The SPS.home’s power socket will be protected by 

a fuse or circuit breaker limiter. This line must not 

power machines with large electrical demands such as air 

conditioning units, refrigerators, etc.).

Avoid the use of extension cables, since the SPS itself 

could be considered as a PdU.

3. 

Press start-stop button 

5

 to start the unit. Its surrounding Led 

will light up and the unit will emit a beep.

It is possible to start the unit without the presence 

of mains power (Coldstart function) by pressing on 

start-stop button 

5

. This, however, is not recommended be-

cause if a mains failure extends beyond the available 

backup, it will be necessary to carry out a forced stop.

In the event of a mains failure and the battery’s backup 

Summary of Contents for SPS.HOME

Page 1: ...SPS HOME USER S MANUAL UNINTERRUPTIBLE POWER SUPPLY UPS...

Page 2: ...2 SALICRU...

Page 3: ...ntents 5 2 Siting and considerations 5 2 1 Siting 5 2 2 Considerations 5 2 2 1 Battery charging 5 2 2 2 Power connected to the SPS HOME 5 3 Connection and commissioning 5 3 1 Procedure to follow 5 3 1...

Page 4: ...by qualified personnel Although no effort has been spared to ensure that the in formation in this user manual is complete and accurate we are not responsible for any errors or omissions that may exist...

Page 5: ...for the correct identification of each of the parts which together with the in structions described in this user manual allows the operations of installation and commissioning to be performed in a sim...

Page 6: ...UPS Part 1 1 General and safety requirements for UPS used in user access areas EN IEC 60950 1 Information technology equipment Safety Part 1 General requirements EN IEC 62040 2 Uninterruptible power s...

Page 7: ...perform this task of protection against mains failures by providing a similar voltage for a period of time Under normal conditions the output of the UPS is the same as the input of the AC power mains...

Page 8: ...will charge irrespective of whether the SPS HOME is switched on or off 5 2 2 2 Power connected to the SPS HOME Check that the loads connected to the power sockets do not exceed the power rating of th...

Page 9: ...ted beep every 0 5 sec for moderate overload or continuous for excessive Normal Tripped Overload Activated by excessive load connected to the device s output sockets Stop the UPS disconnect the load A...

Page 10: ...o load connected to prevent a mains failure from discharging the battery and leaving the loads unpowered Unit has been damaged by a repetition of voltage peaks Contact distributor or seller and failin...

Page 11: ...er surges Battery Element rated voltage 12 V DC Pb Ca sealed maintenance free battery Number of elements Capacity 1 5 Ah 1 5 6 Ah Typical recharge time 8 hours to 90 charge Optical and audible indicat...

Page 12: ...alicru_SA Product Range Uninterruptible Power Supplies UPS Lighting Flow Dimmer Stabilisers DC Power Systems Static Inverters Photovoltaic Inverters Voltage stabilisers Variable frequency drives The T...

Reviews: