Compatibility and Migration 

CompleteView deployments using existing Gen I capture boards are compatible with CompleteView servers 
using Gen II capture boards.  Gen I boards do not need to be replaced, and new systems using Gen II boards can 
be added to existing deployments.  Gen II systems require CompleteView 4.1.  CompleteView 4.1 is compatible 
with both Gen I and Gen II boards, allowing existing systems to be upgraded without replacing hardware. 
 
New system orders of analog cameras will include the Gen II boards by default.  Gen I boards are available for 
replacement, warranty repair and other purposes upon request until the Gen I boards are discontinued. 
 
In some scenarios it may be desirable or necessary to replace existing Gen I boards with a Gen II board.  These 
scenarios include: 

1.

 

If replacing a single Gen I board, that board and others could be replaced with a Gen II board. 

2.

 

If upgrading the operating system on a CompleteView server to a 64 Bit OS (Gen I boards are not 
compatible with 64 bit operating systems). 

 
In order to upgrade to Gen I boards to a Gen II board follow these steps 

1.

 

CompleteView on the target computer needs to be updated to version 4.1.  

2.

 

Order the appropriate replacement Gen II board.  Order either Gen II 8 BRD RPL for the 8 channel Gen 
II board if replacing one or two Gen I cards, or Gen II 16 BRD RPL for the 16 channel Gen II board if 
replacing 3 or 4 Gen I cards. 

3.

 

Once the new board is received, install it in the target CompleteView server. Contact Salient Support to 
have the Gen II board licensed for the appropriate number of channels.  In order to trade the licenses 
from the Gen I boards to the new Gen II board, the old Gen I boards will need to be sent back to Salient.  
Salient Support will issue an RMA to track the return of the Gen I boards. There is no cost for this 
license trade, however a purchase order will be generated for the number of licenses traded, and will be 
billed 30 days after the license are issued to activate the Gen II board.  If the Gen I boards are received 
back under the RMA issued the PO will be canceled. 

 
 

 

Summary of Contents for CEA04

Page 1: ...CompleteView Gen I Gen II Analog Capture Hardware Guide CompleteView Version 4 7 1 ...

Page 2: ...Table of Contents Hardware Overview 3 Compatibility and Migration 4 Gen II Pricing and Ordering 5 Transitioning to IP with Gen II 7 Adding Cameras and Replacing Boards 8 Additional Resources 9 ...

Page 3: ...uters CPU As such any type of compression supported by CompleteView could be used to compress the analog video feed however processing resources were tied up in the compression of analog video Additionally the card came in 4 camera increments so a free PCI or PCI slot was required on the target computer for each 4 camera card Beginning with CompleteView v4 1 Salient provides the Gen II capture boa...

Page 4: ...ting system on a CompleteView server to a 64 Bit OS Gen I boards are not compatible with 64 bit operating systems In order to upgrade to Gen I boards to a Gen II board follow these steps 1 CompleteView on the target computer needs to be updated to version 4 1 2 Order the appropriate replacement Gen II board Order either Gen II 8 BRD RPL for the 8 channel Gen II board if replacing one or two Gen I ...

Page 5: ...6 channel 12 active channels 4 inactive channels CVSW ONE 16A COA16 Gen II 16 channel 16 active channels 0 inactive channels CVSW ONE 20A COA20 Gen II 32 channel 20 active channels 12 inactive channels CVSW ONE 24A COA24 Gen II 32 channel 24 active channels 8 inactive channels CVSW ONE 28A COA28 Gen II 32 channel 28 active channels 4 inactive channels CVSW ONE 32A COA32 Gen II 32 channel 32 active...

Page 6: ...CVSW ENT 16A CEA16 Gen II 16 channel 16 active channels 0 inactive channels CVSW ENT 20A CEA20 Gen II 32 channel 20 active channels 12 inactive channels CVSW ENT 24A CEA24 Gen II 32 channel 24 active channels 8 inactive channels CVSW ENT 28A CEA28 Gen II 32 channel 28 active channels 4 inactive channels CVSW ENT 32A CEA32 Gen II 32 channel 32 active channels 0 inactive channels CVSW ENT 36A CEA36 ...

Page 7: ...e CompleteView administrator to toggle the gen II analog camera license to an IP camera license without sending the card back to Salient Analog licenses can be transitioned to IP one at a time using the Gen II boards allowing for a smoother transition To transition from Analog to IP using a Gen II board open CompleteView Server Configuration 1 Select the camera to be converted 2 On the General Tab...

Page 8: ...ard that contains the correct number of inputs Order the analog channels along with the correct board exchange part number Board exchanges are available for exchanging the 8 channel card to the 16 or 32 channel card as well as from the 16 to the 32 channel card The follow chart summarizes the exchange scenarios and the correct exchange part number Gen II Board Exchange Currently Deployed Card Chan...

Page 9: ...ing and Moving IP Camera Licenses Training http www salientsys com support training we offer both online and classroom training o CompleteView Online Certification Register online for access to interactive training modules covering the Video Alarm Mapping and Web clients o CompleteView Classroom Certification Our traditional classroom training is available throughout the United States Please visit...

Reviews: