11.3.2 Error type B
If type B errors occur, proceed as follows to acknowledge:
• To change to the menu mode, press the white button.
Menu number <6.0.0.0> flashes on the display.
• Press the white button again.
Menu number <6.0.0.0> appears steady on the display.
On the units display, the current incidence (x) as well as the maximum
incidence of the error (y) are displayed in the format “x/y”.
Incidence X < Y
If the current incidence of the error is less than the maximum inci-
dence (Fig. 59):
• Wait for auto reset time.
On the value display, the remaining time until auto reset of the error
is displayed in seconds.
After the auto reset time has run out, the error will be automatically
acknowledged and the status page will be displayed.
NOTE:
The auto reset time can be set on menu number <5.6.3.0> (time input
10 to 300 s)
Incidence X = Y
If the current incidence of the error is equal to the maximum incidence
(Fig. 60):
• Wait until the remaining time is up.
The time until manual acknowledgement is always 300 seconds.
On the value display, the remaining time until manual acknowledge-
ment of the error is displayed in seconds.
• Press the white button again.
The error is acknowledged, and the status page is displayed.
Fig. 58: Error type B, flowchart
1
2
4
7
8
3
5
6
Program
step/query
Contents
1
• Error code is displayed
• Motor Off
• Red LED On
2
• Error counter is incremented
3
Error counter > 5?
4
• SSM is activated
5
> 5 minutes?
6
> 5 minutes?
7
Error acknowledged?
8
End; auto control resumes
Yes
No
Fig. 59: Acknowledging error type B (X < Y)
6.0.0.0
6.0.0.0
S
3/6
75
12.3
E000
Fig. 60: Acknowledging error type B (X = Y)
6.0.0.0
6.0.0.0
6.0.0.0
S
6/6
6/6 S
0
300
12.3
E000
Summary of Contents for IXENS
Page 2: ......
Page 3: ......
Page 8: ...Fig 7 Ixens 13 20 22 21 15 16 17 18 19 14 13 12 11 10 9 8 7 4 3 2 1 6 5 20b 20a ...
Page 75: ...Français Notice de montage et de mise en service Ixens Ixens Bloc 67 ...
Page 137: ...English Installation and operating instructions Ixens Ixens Bloc 129 ...
Page 203: ...Italiano Istruzioni di montaggio uso e manutenzione Ixens Ixens Bloc 195 ...
Page 335: ......