English
Installation and operating instructions Ixens, Ixens Bloc
73
• Only allow persons who do not have a pacemaker to dismantle and
install the rotor for maintenance and repair work.
NOTE:
The magnets inside the motor do not pose a danger
provided the
motor is completely mounted.
As such, the pump assembly does not
pose a special danger to persons with pacemakers, who can safely
approach a Ixens without any restrictions.
WARNING! Risk of injury!
Opening the motor leads to high, suddenly occurring magnetic
forces. These can cause serious cuts, crushing injuries and bruises.
• Do not open the motor!
• Only allow Salmson customer service to dismantle and install the
motor flange and the bearing plate for maintenance and repair
work.
CAUTION! Risk of property damage!
Non-permitted substances in the fluid can destroy the pump.
Abrasive solids (e.g. sand) increase pump wear.
Pumps without an Ex rating are not suitable for use in potentially
explosive areas.
• The intended use includes complying with these instructions.
• Any other use is considered to be outside the intended use.
5
Product information
5.1
Type key
The type key consists of the following elements:
5.2
Technical data
Example:
Ixens 40-42/4,5-xx
Ixens Bloc 32-42/4,5-xx
Ixens
Ixens Bloc
High efficiency flange-end pump as:
I
n-line single pump
Mono
B
loc pump
40
Nominal diameter DN of the flange connection
(for Ixens Bloc: pressure side) [mm]
42
Delivery heads range
(for Q = Q
opt
) [m]
4.5
Rated power [kW]
xx
Variant: e.g.
R1
– without differential pressure
sensor
Property
Value
Remarks
Speed range
500 – 5200 min
-1
Depending on pump type
Nominal diameters DN
Ixens:
40/50/65/80/100 mm
Ixens Bloc:
32/40/50/65/80 mm (pressure side)
Pipe connections
Flanges PN 16
EN 1092-2
Permissible min./max. fluid temperature
-20 °C to +140 °C
Depending on fluid
Ambient temperature min./max.
0 to +40 °C
Lower or higher ambient
temperatures on request
Storage temperature min./max.
-20 °C to +70 °C
Maximum permissible operating pressure
16 bar
Summary of Contents for IXENS
Page 2: ......
Page 3: ......
Page 8: ...Fig 7 Ixens 13 20 22 21 15 16 17 18 19 14 13 12 11 10 9 8 7 4 3 2 1 6 5 20b 20a ...
Page 75: ...Français Notice de montage et de mise en service Ixens Ixens Bloc 67 ...
Page 137: ...English Installation and operating instructions Ixens Ixens Bloc 129 ...
Page 203: ...Italiano Istruzioni di montaggio uso e manutenzione Ixens Ixens Bloc 195 ...
Page 335: ......