background image

5

5.0

Calibration

This scale comes with the calibration jumper on the PC board in the 
CALIBRATE position. The calibration instructions below are written for this 
jumper condition.

If the user wants to lock the calibration they must access the PC board and 
more the jumper. See the next section 

6.0 Accessing the PC board and 

Locking/Unlocking Calibration 

on page 6

 for instructions.

1.

Be sure to have the proper test weights on hand. For Model 405-6 
you should have 6 kg or 12 lb weights. For Model 405-15, you should 
have 15 kg or 30 lb weights.

2.

Remove all weight from the scale platform and be sure the scale is 
turned off.

3.

Press and hold the 

Tare/Units

 key, and then press the 

On/Off/Zero

 

key until…

CAL-0

 appears.

4.

Release the two buttons. 

5.

Press the 

On/Off/Zero

 key…

0

 in 

CAL-0

 will flash briefly, then 

CAL-F

 is displayed.

6.

Press the 

Tare/Units

 key to choose the unit of standard weight in 

calibration…

The blue annunciator will light next to the active unit of mea-
sure.

7.

Load full capacity on the scale platform. That is 6 kg or /12 lb for 
Model 405-6, or 15 kg / 30 lb for Model 405-15. Press the

 On/Off/

Zero

 key…

F

 in 

CAL-F

 will flash briefly then 

CAL-0

 appears again.

8.

Remove the weight from the scale platform, and press the 

On/Off/

Zero

 key…

0

 in 

CAL-0

 flashes until calibration is complete.

9.

The scale will restart in normal weighing mode. If 

CAL.Er

 is 

displayed, there is an error in calibration and you need to perform 
steps 

1

 through 

8

 again.

10.

In steps 

3

 through 

5

, press the 

On/Off/Zero

 key repeatedly to abort 

the calibration procedure. 

Summary of Contents for 405

Page 1: ...d accuracy of your scale Only use on a stable vibration free surface Handle with care Gently apply all items to be weighed onto the weighing platform Although this scale is designed to be quite durabl...

Page 2: ...ff Zero key See illustration below On Off Zero key The On Off Zero key is used to turn the scale on or off and to zero the scale ON OFF Function When scale is off press the On Off Zero key to turn on...

Page 3: ...ator on the left of the display will be lit and the NET annunciator will be off The scale will not zero if the display is beyond 5 of full capacity The display will show 0 or 0_____ then return to the...

Page 4: ...Place container to be tared on the scale and press the Tare Units key for less than five seconds Net annunciator lights when a tare is active Place item s to be weighed in the container Net weight is...

Page 5: ...ess the On Off Zero key until CAL 0 appears 4 Release the two buttons 5 Press the On Off Zero key 0 in CAL 0 will flash briefly then CAL F is displayed 6 Press the Tare Units key to choose the unit of...

Page 6: ...ation mode for the scale you must access the PC board and move a jumper Follow these steps 1 Remove the scale platform 2 Use a 5mm hex wrench to remove the two screws holding the platform support to t...

Page 7: ...Figure 1 2 shows the older version of the main board and the calibration jumper JP1 The jumper is shown inside the red oval The oldest version of the main board is shown in Figure 1 3 Figure 1 1 Curre...

Page 8: ...igure 1 2 is in the calibration unlocked position The scale can be calibrated with the jumper on the two pins on the right side Pull the jumper up and move it to the left two pins to lock calibration...

Page 9: ...ide the small red rectangle It is shown in the calibration locked position The scale cannot be calibrated with the jumper on the two bottom pins Pull the jumper up and move it to the top two pins to u...

Page 10: ...capacity above the calibration zero point when scale is turned on OR The weight reading is more than 5 of full capacity above the power on zero point when you press the On Off Zero key 0______ Power o...

Page 11: ...30 000lb x 0 005lb 2 Display seven red 0 56 seven segment LED digits display with eight LED diodes ZERO NET AC CHG LB KG G OZ Below are examples of the display showing 5 340kg in all the possible unit...

Page 12: ...ower supply is lower than 5 7V 0 1V but over 5 4V 0 1V the scale will display Lo bAT and the other current display alternatively If AC adapter is used to charge battery or to power scale the rocker sw...

Reviews: