KEY DESCRIPTIONS:
HOLD
UNIT
ON
ZERO
OFF
COUNT
1. UNIT:
1) Select weight units: kg, lb., or oz.
2. ON/ZERO/OFF:
1) Power on the indicator.
2) Press and hold this key for 3 seconds to power off.
3) This key is “Zero” feature if load is below 2% of full
capacity or a negative value.
3. HOLD:
1) When the weight is unstable, press this key to hold the
weight value.
2) To release Hold feature, press the HOLD key again.
4. COUNT
1.) Press the count key and the indicator will say “A 10”. For
more samples press the count key additional times.
2.) When the stable indicator comes on the scale should
indicate a count of 10 pieces.
3.) Place an unknown amount on the scale and it will indicate
the count.
4.) To exit the count mode press the “Unit” key.
5
CALIBRATION PROCEDURE
1. Press ON/ZERO/OFF key without releasing, and then press
UNIT key 3 times to enter test mode, the display shows zero
count (1000-6000).
2. Press ON/ZERO/OFF key and display shows “0”.
3. Load the calibration weight. (Note: Please see following table-
calibration weight):
CAP.
CALIBRATION
WAY
Kg
SPAN
RANGE
CALIBRATION
WEIGHT
Lb.
SPAN
RANGE
CALIBRATION
WEIGHT
¼
1000
∼
5000
500 g
910
∼
4550
1 lb.
½
2000
∼
10000
1 kg
1820
∼
9100
2 lb.
2.5 kg
3 kg
Full
4000
∼
20000
2 kg
4550
∼
22500
5 lb.
¼
1000
∼
5000
2 kg
910
∼
4550
2 lb.
½
2000
∼
10000
5 kg
2270
∼
11350
5 lb.
5 kg
6 kg
Full
5000
∼
25000
2 kg
4550
∼
22500
10 lb.
¼
1000
∼
5000
2 kg
910
∼
4100
5 lb.
½
2000
∼
10000
5 kg
1820
∼
9100
10 lb.
10 kg
15 kg
Full
4000
∼
20000
10 kg
4100
∼
18000
20 lb.
¼
1000
∼
5000
5 kg
910
∼
4550
10 lb.
½
2000
∼
10000
10 kg
1820
∼
9100
20 lb.
25 kg
30 kg
Full
4000
∼
20000
20 kg
4000
∼
20000
50 lb.
¼
1000
∼
5000
10 kg
910
∼
4550
20 lb.
½
2000
∼
10000
20 kg
1820
∼
9100
40 lb.
50 kg
60 kg
Full
4000
∼
20000
40 kg
4000
∼
20000
100 lb.
Summary of Contents for BS150
Page 8: ...6 Outline Drawing 7...
Page 9: ...8...