background image

3

2.0

General Scale Information

Read this user manual before using the scale so you understand the 
operating features. 

Do not overload the scale or throw heavy things on the scale. Damage 
from overloading and abuse is not covered by the guarantee.

Keep the scale clean with a damp cloth and mild cleaning solution.

1.

Set the scale on a level, solid surface and screw the base feet in or 
out to bring the bubble to the center of the level.

2.

Turn the unit on by pressing the 

ZERO

 key.

The beeper will sound, the display will show the version number 
and the battery voltage level (

dc-x.xx

), then goes into the display 

self-check ends with the 

ZERO

 annunciator lighting. The scale is 

now ready to use.

3.

To turn the scale off, press the 

OFF

 key. The scale will turn off 

automatically after 10 minutes if the scale display is at zero and 
there is no keypad operation. You can set the auto-off time in the 
Configuration menu. See 

A-oFF 

on page 9

. There is also a power 

saving feature. After 40 seconds of scale inactivity the scale goes 
into auto power saving mode and the display shows a small 

o.

 To 

wake the scale up, place a weight on the scale platform.

4.

If the battery voltage drops below 5.6V, the scale will turn off 
automatically. There is a battery level annunciator on the left side of 
the display. If three of the lights are lit, the voltage is 6.3V or higher. 
If two lights are lit, the voltage is between 6.0V and 6.3V. If only one 
light is lit, the voltage is lower than 6.0V and the unit should be 
recharged.

5.

Battery charging: Power is supplied by a built-in rechargeable lead 
acid battery (6V/4.5Ah). It shows 

-bAtLo-

 when the voltage is low 

and the scale is at zero. The scale can be used for a while, but the 
battery should be charged as soon as possible.  
 
To charge the battery, plug the AC power cord into an appropriate, 
grounded outlet and charge for 12 hours. 
 
If the scale is unused for a long period of time, charge the battery at 
least every 3 months. 

If after charging the battery life is very short, install a new battery.

6.

If there is no active tare, you can zero the displayed weight if it is 
lower than 4% of full capacity. To zero the scale, press the 

ZERO

 

key. The 

ZERO

 annunciator will light.

Summary of Contents for C3235

Page 1: ...ront panel of the unit The front panel includes the display window the annunciators arrayed around the display the four keys and the bubble level Figure 1 1 C3235 front panel NOTE This product is rate...

Page 2: ...ust recharge the battery soon CAEnd This is displayed when calibration is finished Err 0 A zero point error has occurred C_End This is displayed when the battery is fully recharged ZERO key Press this...

Page 3: ...e inactivity the scale goes into auto power saving mode and the display shows a small o To wake the scale up place a weight on the scale platform 4 If the battery voltage drops below 5 6V the scale wi...

Page 4: ...emove the item s and repeat steps 2 through 4 for the next item s 4 0 Tare weighing 1 Power up the scale 2 Zero the scale if necessary by pressing the ZERO key 0 is displayed 3 Place the item to be ta...

Page 5: ...weight is displayed and the Over Accept or Under annunciator lights You must set the acceptable window parameters in the Configuration menu which is described in rAnGE on page 6 4 Remove item from the...

Page 6: ...h of these parameters is described below Accessing the Configuration Menu and Setting Parameters To access the Configuration menu press and hold the F key for three seconds rAnGE the first menu item i...

Page 7: ...eighed Remember as you set the values for the lower and upper ranges that the decimal does not appear on the display but you enter the values as if it were For example If you want 2 85 pounds as the h...

Page 8: ...through the choices Lb Lb This is the pounds unit of measure Lb oZ This is the pounds ounce unit of measure PcS This is the counting function HG This stands for KG or kilogram G This is the gram unit...

Page 9: ...o enter 25 you must press the TARE key three times to move the flashing digit to the right three times then enter 2 and 5 so the display looks like this 00025 After the last digit is entered the scale...

Page 10: ...s displayed This is the filter setting The noisier the environment the scale is in the higher the filter setting you should choose This means if the scale sits in a place that is subjected to vibratio...

Page 11: ...he choices When your choice is displayed press the TARE key 5 The function is set and the scale returns to normal weighing mode 7 0 Calibration You can calibrate this scale using single point or multp...

Page 12: ...hold the TARE key to enter calibration and repeat the calibration process Multipoint Calibration Follow these steps for multipoint calibration of the scale You will need test weights equal to 1 3 2 3...

Page 13: ...ter and press the TARE key when the display becomes stable The display shows c 0 with the c flashing At this point you can input a gravity adjustment 10 Press ZERO to increment the factor by one Press...

Page 14: ...15 30 Max Cap 3kg 6lb 6kg 12 lb 15kg 30lb Division Size 0 5g 0 01 lb 1g 0 02 lb 2g 0 05 lb Max Tare 100 Accuracy Class III Pan size 7 5 x 9 Working Temperature 23 95 F 5 35 C Power 6V4 5Ah rechargeab...

Page 15: ...15...

Page 16: ...ll Weighing Products 1000 Armstrong Dr Fairmont MN 56031 Toll free 800 637 0529 Tel 507 238 8702 Fax 507 238 8271 e mail sales salterbrecknell com www salterbrecknell com October 2014 C3235_u fm AWT35...

Reviews: