CHAPTER 5 : CALIBRATION
1. Place a large flat plate or batons across the trolley’s weighing platter.
2. Press and hold the ON key and press UNIT key 3 times, display shows zero count, which should read
between 500 to 5000 counts.
3. Press TARE key.
4. Load an appropriate calibration span load (see Chapter 4) onto the center of the scale The display shows
the span count which should be between 4000 to 6000 counts.
5. Press TARE key, display shows “CAL” and then the calibration weight.
Note: If the zero count is not within 500 to 5000, you will need to replace the resistor R1 on the PCB card
(Figure 8). This resistor will normally be 100K~300K.
Figure 8
CHAPTER 6 : SPARE PARTS LIST
Item
Part No.
Rear wheel assembly
MQ10002-0
Front wheel assembly
MQ10001-0
100 – 240V Adapter
(UK, EU, USA)
ME00264-4
Display head assembly – c/w battery
and lead
SE90371-0
Rechargeable battery pack
ME00240-7
Load Cells (pair)
SS00079-0
Overlay
MP10031-8
Snap hooks
MM10020-7
J box PCB
ME00191-5
User Manual
76103-342