SETTING UP YOUR MS-20 SCALE

To insure that your scale operates correctly, position the scale on a level sturdy
worktop.

The display head can be either attached to the wall or positioned in front of the
scale.

Pull down feet on back of display head enable the operator to change the
viewing angle of the display head.

Any excess cable can be stored in the cavity on the underside of the display
head.

 

POWER SUPPLY

The MS-20 uses 9V alkaline battery or
9V 100mA AC adapter.

CAUTION:

 always connect the AC

adapter to the MS-20 before
connecting to the mains power supply.

Disconnect from the mains power
supply before disconnecting the
adapter from the MS-20

 

KEY FUNCTION

ON/TARE

    (1) Press once to switch scale on.

 

  

OFF -

    

(2) Press while scale is switched on to 

          re-zero the scale.

    (

3) Press and hold this key for 2 seconds

          to switch scale off. Scale will auto shut-off
          if not used after 120 seconds

 

 UNIT   

-  

Selects between kg mode and lb

 

mode.

HOLD  

-     

When pressed the displayed weight  will be

           

held on the display once the  weight becomes
stable.

                              

   By repressing the Hold key again will release

                                            the held display and allow the scale to return
                                            back to normal weighing mode.

 

ERROR MESSAGES

1. Low Battery

2. High zero counts

3. Low zero count

4. Overload

 

SPECIFICATIONS

      Model #                   MS-20

Maximum Capacity

44 lb / 20 kg

Readability

½ oz / 10 g

Weight units

lb / kg

Power supply

9V alkaline battery or 9V 100mA AC adapter

Dimensions

20” x 12” x 2 ½” / 505mm x 300mm x 65 mm

Display

1.0” LCD display with 4 active digits

Tray

Plastic top cover

Operating Temperature

5

°

C ~ 35

°

C

Function keys

ON/TARE/OFF, UNIT, HOLD

   

CALIBRATION PROCEDURE 

1) With the scale switched off, press and hold the “ON/OFF/TARE key, without 
releasing press the kg/lb key three times and then release. 
2) Display will show zero (

4000~12000

). 

3) Press the “UNITS” key, switch to LB mode or KG mode 
4) Press “ON/OFF/TARE” key once. 
5) Display will show “CAL” and then “0”. 
6) Load 20kg weight onto the scale, or load 40 lb in case of switched to LB mode 
at step 3. 
7) Display will show span count (

8000~16000

) for KG mode or (

7260~14520

) for 

LB mode. 
8) Press “ON/OFF/TARE” key again. 
9) Display will show “CAL” and then “20.00 kg” for KG mode or “40:00 lb” for LB mode.   
10) Remove the weight from the scale and the calibration is finished

.

 

 