background image

1

Pegasus Floor Scale Installation Guide

Pegasus Floor Scale Installation Guide

For Shear Beam, Mild and Stainless Steel Scales and Poly Top Floor Scales

Proper scale installation provides accurate and reliable system operation. It is
essential to mount the scale on a flat, level, and solid surface. The load-
bearing surface areas should be within ±1/16 inch of the same level plane.
Minor irregularities in the floor may be compensated for with the feet adjust-
ments. The scale should not rock on the load-bearing surface areas and
these areas should not give under loads.

  

Figure 1

Pegasus scales

This scale is precalibrated and is ready for installation and use.

• Place the Pegasus deck on a solid, level surface. Use the leveling feet

to eliminate any rocking of the deck.

• Mount the indicator using the bracket provided. This will accommodate

desk or wall mounting.

• Uncoil the cable from under the scale and route it to the indicator. The

cable should be protected from traffic to avoid damage. Connect the
cable to the indicator. See note at left.

• Apply power to the indicator and verify proper scale performance.

Installation

Washdown systems will need to
have the cable connected to
the junction box. Use the
indicator manual to insure
proper wiring.

Summary of Contents for Pegasus Floor Scale

Page 1: ...reas and these areas should not give under loads Figure 1 Pegasus scales This scale is precalibrated and is ready for installation and use Place the Pegasus deck on a solid level surface Use the level...

Page 2: ...Yellow Sense White Signal Orange White Shield Red Signal Blue Sense Black Excitation Remove the access plate and the junction box cover plate Attach the leads of the indicator interface cable to TB5...

Page 3: ...he value of internal zero for your particular indicator refer to yourindicator sServiceManual 3 Use test weights equal to 20 25 of full capacity and obtain a displayed weight value for the test weight...

Page 4: ...ibrated Final Span Calibration To replace one or more weight sensor follow this procedure 1 Obtain access to junction box and the junction box cover 2 Disconnect weight sensor cable from junction box...

Page 5: ...y scales You can use shim stock under these floor plates to obtain a level mounting surface Drill the four corner holes through the shim stock but leave the center intact These drawings are to scale Y...

Page 6: ...6 Pegasus Floor Scale Installation Guide 10K Scales Floor Plate Part Numbers SST 28273 0012 1 4 thick SST 28273 0020 1 2 thick...

Page 7: ...774 0011 Junction Box ABS plastic 1 1 41244 0018 Foot Assy 4 41244 0026 Foot Assy 4 53455 0017 Foot Assy 4 53455 0033 Foot Assy 4 52655 1064 Bolts Hex Cap 20 x2 8 8 22408 1034 Bolts 20 x1 75 8 22408 1...

Page 8: ...eigh TronixInc 03 24 03 PEGASUS_i P65 PN43008 0010Ae1 PrintedinUSA P O Box 9533 3620 Central Ave NE Minneapolis MN 55418 Toll free 800 637 0529 Tel 612 781 4211 Fax 612 781 4320 e mail sales salterbre...

Reviews: