background image

20000 

4.0000  40.000  400.00  4000.0  40000  400000 

25000 

5.0000  50.000  500.00  5000.0  50000  500000 

30000 

6.0000  60.000  600.00  6000.0  60000  600000 

35000 

7.0000  70.000  700.00  7000.0  70000  700000 

40000 

8.0000  80.000  800.00  8000.0  80000  800000 

50000 

10.0000  100.000  1000.00  10000.0  10000

1000000 

60000 

12.0000  120.000  1200.00  12000.0  12000

1200000 

70000 

 

14.0000  140.000  1400.00  14000.0  14000

1400000 

75000 

15.0000  150.000  1500.00  15000.0  15000

1500000 

80000 

16.0000  160.000  1600.00  16000.0  16000

1600000 

100000 

20.0000  200.000  2000.00  20000.0  20000

2000000 

 
Table8: (Capacity unit is kg or lb) 

Division set by P8 and P9(

P8=2)

 

Resolution 

set by P7  0.0005  0.005 

0.05 

0.5 

50 

500 

0.2500  2.500 

25.00 

250.0 

2500 

25000 

600 

0.3000  3.000 

30.00 

300.0 

3000 

30000 

750 

0.3750  3.750 

37.50 

375.0 

3750 

37500 

800 

0.4000  4.000 

40.00 

400.0 

4000 

40000 

1000 

0.5000  5.000 

50.00 

500.0 

5000 

50000 

1200 

0.6000  6.000 

60.00 

600.0 

6000 

60000 

1500 

0.7500  7.500 

75.00 

750.0 

7500 

75000 

2000 

1.0000  10.000  100.00  1000.0  10000  100000 

2400 

1.2000  12.000  120.00  1200.0  12000  120000 

2500 

1.2500  12.500  125.00  1250.0  12500  125000 

3000 

1.5000  15.000  150.00  1500.0  15000  150000 

3500 

1.7500  17.500  175.00  17500.0  17500  175000 

4000 

2.0000  20.000  200.00  2000.0  20000  200000 

5000 

2.5000  25.000  250.00  2500.0  25000  250000 

6000 

3.0000  30.000  300.00  3000.0  30000  300000 

7000 

3.5000  35.000  350.00  3500.0  35000  350000 

7500 

3.7500  37.500  375.00  3750.0  37500  375000 

8000 

4.0000  40.000  400.00  4000.0  40000  400000 

10000 

5.0000  50.000  500.00  5000.0  50000  500000 

12000 

6.0000  60.000  600.00  6000.0  60000  600000 

15000 

7.5000  75.000  750.00  7500.0  75000  750000 

20000 

10.0000  100.000  1000.00  10000.0  10000

1000000 

25000 

12.5000  125.000  1250.00  12500.0  12500

1250000 

30000 

15.0000  150.000  1500.00  15000.0  15000

1500000 

24 

Summary of Contents for PS-500

Page 1: ...PS 500 SCALE Operation Manual Contents subject to change without notice Version 1 0 2006 01 10 Declarations of compliance...

Page 2: ...iques de la Classe A prescrites dans le R glement sur le brouillage radio lectrique edict par le minist re des Communications du Canada Warnings Electrical installation For your protection all mains 1...

Page 3: ...e radio computer or other electronic device These devices emit RF and can causeunstablescalereadings Ifyourscaleeverperformspoorly trymovingthescale to a different room or location Avoid using in cond...

Page 4: ...ed on a scale following are required on the load cell set to be used with this indicator 1 Sensitivity 0 3mV V 3mV V must be fit to 0 2uV display grad 2 Input Resistor 80 3 Output Resistor 10 K LOADCE...

Page 5: ...ng range P13 set the scale will show 0 zero point is over the setting range or 0_ _ _ _ zero is below the setting range 3 2 In normal weighing mode and hold down time longer than 3s 1 2 3 Same meaning...

Page 6: ...will display CAP that means the following data is the full capacity according to your setting of display resolution P7 display division value P8 location of decimal point dot in calibration unit P9 an...

Page 7: ...nd return back to step 5 for re calibration 8 When CAL P0 is shown again that means the scale will calibrate scale s zero point again Now you can press ON OFF ZERO to exit the calibration mode or Move...

Page 8: ...splay 1 P A B Item A parameters and one digit can be input 2 P A BC Item A parameters and two digits can be input 3 PAB C Item AB parameters and one digit can be input 4 PAB CD Item AB parameters and...

Page 9: ...ut format is same as x 1 X 6 Whenthe scaleis stable it willoutputthe currentgross weight tareweight and net weight data including unit automatically one time and not accept data The output format is s...

Page 10: ...lb Not available 0 01 lb 0 005 kg 0 01 lb 0 2 oz 0 1 lb 0 05 kg 0 1 lb 2 oz 15 1 lb 0 5 kg 1 lb Not available 10 lb 5 kg 10 lb Not available 0 0002 lb 0 0001 kg 0 0002 lb Not available 0 002 lb 0 001...

Page 11: ...signal is NOT within the power on zero point range x 0 Choose current weight as current power on zero point x 1 Choose calibration zero point as power on zero point x 3 Choose power off zero point as...

Page 12: ...t data is filled by _ If the zero point is error it will return nine _ characters b The character will be for negative weight or a space character for positive weight Minus sign follows after the firs...

Page 13: ...urn off the scale 8 Command all others Response Unrecognized command LF CR ETX 2 5 Output status bit meaning Table5 The status bits definition Bit Byte 1 H1 Byte 2 H2 Byte 3 H3 0 stable 0 not under ca...

Page 14: ...80 000 800 00 8000 0 80000 800000 100000 10 0000 100 000 1000 00 10000 0 10000 0 1000000 Table7 Capacity unit is kg or lb Division set by P8 and P9 P8 1 Resolution set by P7 0 0002 0 002 0 02 0 2 2 2...

Page 15: ...50 37500 800 0 4000 4 000 40 00 400 0 4000 40000 1000 0 5000 5 000 50 00 500 0 5000 50000 1200 0 6000 6 000 60 00 600 0 6000 60000 1500 0 7500 7 500 75 00 750 0 7500 75000 2000 1 0000 10 000 100 00 10...

Page 16: ...ignal is too large 6 _ _ _ _ _ weight signal is too small 7 EEP E0 the EEPROM can t be accessed 8 EEP E1 The parameters are not same with backup data 9 EEP E2 The setting parameter s is not in normal...