background image

Manual_SAL

TO_GEO_VDS_ENG_08-13

www.saltosystems.com

SALTO Systems - SALTO Geo user manual

8

CONFIDENTIAL - This document contains confidential and privileged information. 

The reproduction of any part of the document is strictly prohibited without the prior written consent of Salto Systems S.L.

INSTALLATION

 

3 - Prepare the cylinder for the installation on the door (for model G9x3)

  

 Remove one of the knobs in order to be able to fit the cylinder

 

For a correct installation

 

4 - fix it to the door

 

5 - Screw it to the mortise lock

PA

IRE

D*

360ºx3

2 mm allen key

(not included)

External Knob

For a correct installation the body 

need to excel 3mm from the door 

surface

At this point do not close the door 

without having programmed the 

cylinder first

Model GxE2

Model GxE3

Door

li

le

0 - 3mm max.

Summary of Contents for XS4 Geo

Page 1: ...ctronic cylinder lock Fully integrated with the SALTO XS4 platform GEO is a versatile cost effective solution and its compact size and easy installation makes it the ideal electronic locking system fo...

Page 2: ...rotection against access to hazardhous areas resistance against ingress of foreign particules and detrimental entry of water 5 Mechanical certifications against vandalisme 5 Fireproof certifications 5...

Page 3: ...ey is always to be stored securely so that it is accessible only to the authorised person If a key gets lost the electronic cylinder is to be replaced immediately or by changing of the codification pu...

Page 4: ...humbturn GxE21xxxxx E2 Euro profile cylinder with thumbturn Antipanic function GxE21xxxxxA E3 Euro profile double cylinder double knob GxE31xxxxx GxE3 GxE1 GxE2 le 10 38 43 38 43 le 10 L le li L 43 38...

Page 5: ...1 2011 09 ETSI EN 301 489 3 2002 08 Security requirements EN 60950 1 2007 Following the provisions of the directive 2004 108 CE Electromagnetic Compatibility and the directive 2006 95 CE Low Voltaje...

Page 6: ...er can be assigned to a calendar and a time table consists of up to 8 different time intervals with a resolution of 10 minutes assigned to each day of the week You can also distinguish between holiday...

Page 7: ...L INSTALLATION 1 unpack 2 Remove the knob to connect the battery 2 Remove the battery protection 3 Prepare the cylinder for the installation on the door for model GxE2 SP220764 not included 2 5 mm all...

Page 8: ...L INSTALLATION 3 Prepare the cylinder for the installation on the door for model G9x3 Remove one of the knobs in order to be able to fit the cylinder For a correct installation 4 fix it to the door 5...

Page 9: ...strategic points around the building The online points uploads and downloads user related information that is then used to permit control or deny access BATTERIES Low battery status The low battery s...

Page 10: ...ument is strictly prohibited without the prior written consent of Salto Systems S L BATTERIES Change the batteries The new SALTO Geo Cylinder permits to change the batteries without needing to open th...

Page 11: ...user card that has access to the door and open the door the cylinder will remain engaged for a few second the end of the time out will be then activated Low battery status After presenting a valid use...

Page 12: ...a reset of the electronic The cylinder memory will not be erased To show this reset the cylinder will show an orange light with a lite sound Access granted Toogle ROM or RW systems After presenting a...

Page 13: ...ange blinking plus a combination of acute and high pitched beeps with a final long orange light that mean that the cylinder gear is broken Security error When the cylinder shows continuous blinking li...

Page 14: ...ms com SALTO Systems SALTO Geo user manual 14 CONFIDENTIAL This document contains confidential and privileged information The reproduction of any part of the document is strictly prohibited without th...

Page 15: ...ms com SALTO Systems SALTO Geo user manual 15 CONFIDENTIAL This document contains confidential and privileged information The reproduction of any part of the document is strictly prohibited without th...

Page 16: ...systems pl SALTO Systems Finland Helsinki www saltosystems fi SALTO SYSTEMS DENMARK kalundborg www saltosystems dk SALTO SYSTEMS NETHERLANDS Amsterdam www saltosystems nl Evvasalto Access AB Sweden St...

Page 17: ...tions ES Por medio de la presente Salto Systems S L Arkotz Kalea Pol Lanbarren 9 20180 Oiartzun Spain declara que este equipo de control de accesos cumple con los requisitos esenciales y cualesquiera...

Reviews: