Assembling the GFA Module

To assemble the GFA module:

1.

Grease the inside of the idler gears and place over the shafts.

2.

Repeat for all idler gears. The number of idler gears depend on the configuration of the GFA module.

3.

Insert the needle roller bearings. Make sure to insert as many needle roller bearings as there is
space for. There should not be any gaps.

4.

Make sure that the parallel pin is inserted.

5.

Apply grease to the idler gears.

6.

Apply grease to the socket gear and place it in the housing. Make sure to place it in the right direc-
tion, according to the specification.

7.

Place the upper part of the housing on top of the lower part. Use a press tool and press evenly over
the housing.

8.

Make sure that there is no gap between the upper and lower parts of the housing.

9.

Grease the inside of the input gear and the needle carrier. Place the needle carrier in the input gear.

10. Use a press tool to push the ball bearing onto the input gear. Use a cylinder with the correct mea-

surements to make the ball bearing go all the way down.

11. Insert the input gear into the bearing housing.

12. Place the nut over the bearing housing.

13. Place the cover plate on the collar back latch. Grease the pawl and spring and insert into the collar

back latch.

The collar back latch can include a torque arm flange depending on the configuration.

14. Push in the pawl and put the collar back latch over the bearing housing. The pawl should go into one

of the two grooves of the input gear. Depending on the gear stage and the desired rotational direc-
tion, the collar back latch can be placed either with the cover plate facing downwards 

(A)

 or upwards

(B)

.

GFA Gear Model

Tightening Rotational
Direction of Output Gear

Mounting Direction of
Collar Back Latch

2-stage

Clockwise

Cover plate facing downwards, image 

A

Counterclockwise

Cover plate facing upwards, image 

B

3-stage

Clockwise

Cover plate facing upwards, image 

B

Counterclockwise

Cover plate facing downwards, image 

A

15. Turn the input square all the way to locked position. Make sure that the output gear is in open posi-

tion and insert the input gear into the housing. The teeth of the gears should mesh. Push the input
gear all the way down until the input gear is flush with the housing. Make sure that the output gear is
in open position when the input gear is in locked position.

16. Secure the housing in a vice and insert the cover cap into the housing. Push the input gear up from

below while tightening the cover cap.

17. Tighten the screws.

18. Use a grease gun to fill the housing with grease through the grease nipple. Note that the GFA mod-

ule can have a different amount of grease nipples depending on the model.

19. Screw the adapter onto the bearing housing until it stops. Secure the housing in a vice and tighten

the nut.

Summary of Contents for GFA-OOT

Page 1: ...from Serial No Product Instructions Open end and Offset Geared Front Attachments WARNING Read all safety warnings and instructions Failure to follow the safety warnings and instructions may result in...

Page 2: ...2 Saltus Industrial Technique AB 9839 1814 01 Table of Contents EN Product Instructions 3...

Page 3: ...ch if not avoided will result in death or se rious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION used with the saf...

Page 4: ...GFA module The GFA module comprises a housing which contains a number of gears that is the gear stage The gear stage depends on the length of the GFA module The output gear or output socket can be of...

Page 5: ...y Instructions The assembly procedure varies depending on the configuration Make sure that the square drive of the drive unit 1 matches the input gear profile square hole of the GFA module 2 Functiona...

Page 6: ...ing it in one direction should lock the wheel In the other di rection the gear wheel should be turned easily The direction for locking clockwise or counterclock wise depends on the configuration of th...

Page 7: ...priate lighting for the work task Select the appropriate tool for the work task In noisy environments use ear protection equipment Use high quality inserted tools and consumables to minimize exposure...

Page 8: ...being used Wrong Parameter File might cause too high torque with bodily injury as a result Compare the maximum torque which is shown in the controller with the maximum torque stated in the stated tech...

Page 9: ...ly Clean the GFA system Inspect the system for any damage Check all fastenings of the system Run functional tests and listen for any abnormal noise At least after every 30 000 tightenings Lubricate th...

Page 10: ...p 3 Remove the bearing housing 4 Loosen the hex screws The module can be fastened with two or four hex screws depending on the model 2 3 or 4 stage 5 Open the housing using a flat screwdriver 6 Remove...

Page 11: ...GFA OOT EN Service Saltus Industrial Technique AB 9839 1814 01 11...

Page 12: ...e collar back latch can include a torque arm flange depending on the configuration 14 Push in the pawl and put the collar back latch over the bearing housing The pawl should go into one of the two gro...

Page 13: ...GFA OOT EN Service Saltus Industrial Technique AB 9839 1814 01 13...

Page 14: ...tool information see the spare parts list of the specific GFA model 3 Remove the adapter together with the drive unit from the GFA unit 4 Fasten the drive unit in a vice Loosen the adapter clockwise t...

Page 15: ...ve unit and the adapter 2 Apply Loctite 2701 or similar to the threads of the drive unit 3 Fasten the drive unit in a vice and tighten the adapter 4 Fasten the GFA in a vice and attach the adapter to...

Page 16: ...strong force It is recom mended to use a heat gun to facilitate the loosening 4 Loosen and remove the bearing shell adapter from the fork adapter The bearing shell is fixed with Loctite Loosening the...

Page 17: ...the angle head 3 Clean the threads Apply Loctite 2701 or similar to the bearing shell adapter and push it into the fork adapter Note this is not the same bearing shell as the one for the angle head i...

Page 18: ...Service EN GFA OOT 18 Saltus Industrial Technique AB 9839 1814 01...

Page 19: ...ecycling Environmental Regulations When a product has served its purpose it has to be recycled properly Dismantle the product and recycle the components in accordance with local legislation Batteries...

Page 20: ...or copying of the contents or part thereof is prohibited This applies in particular to trademarks model denominations part numbers and drawings Use only authorized parts Any damage or malfunction caus...

Reviews: