24
Display in [select splice mode] menu.
Pull test
If [pull test] is set [on], after splicing, open the winder-proof
cover, or press [set] button to do pull test.
Estimated loss
The estimated loss is an estimate of splicing loss. The fusion
splicer calculates the loss of the splicing point according to the
optical fiber image, and has some deviation from the real value.
The loss estimation algorithm is based on single-mode optical
fiber with a transmission wavelength of 1.31
μ
m. The estimated
value is good reference in the case of good splicing condition, but
it can not be used as the basis for acceptance of the project.
Cleaving angle
Either side of the cleaving angle of 2 fibers is over than the
selected cleaving angle limit, and error information will be
displayed.
Space
Set the alignment and pre-splicing discharge, the distance between
the left and right fiber ends.