28
Pause one
If [pause one] is set “on”, splicing will be ended when
the fiber is pushed in right place, and user can see the
cleaving angle.
Pause two
If [pause two] is set “on”, splicing will be ended after
completion of alignment.
Alignment again
Alignment will lose efficacy after long state of [pause
two], after which, fusion splicer will align again. If
Alignment again is set “off”, when fiber axial
displace, it’s suggested to choose manual splicing
mode instead of alignment again mode.
Faulty ignorance
Neglect the splicing fault, such as the cleaving angle is
bigger than the maximum value. If set this function
“on”, splicing can be continued.
Pull test
If pull test is set “on”, then when splicing completed,
turn on the winder-proof cap, pull test could be
executed.