ENGLISH
6. GENERAL FUNCTIONING OF THE CONTROL PANEL
6.1
General functioning
SETUP PREMI
PAG + MAN 10s
ON
THIS SCREEN IS DISPLAYED ONLY IF THE MAINS
SUPPLY WAITING FUNCTION IS ENABLED
IN THE SETUP MENU. TO EXCLUDE THE
WAITING TIME PRESS
RESET
400 V 13.2A
Cf 0.80 0 h
MAINS WAIT. 1 m
RESET TO START
THE OPERATION SCREENS RELATING TO THE CHOSEN
APPLICATION ARE DISPLAYED BELOW
COS
φ
= SEE CHAPTER 6.2
CLEAN WATER = SEE CHAPTER 6.3
SEWAGE = SEE CHAPTER 6.4
4-20mA bar = SEE CHAPTER 6.5
4-20mA meters = SEE CHAPTER 6.6
}
6.2 Application cos
φ
THE FOLLOWING SCREEN DISPLAYS:
- MEASURED VOLTAGE
- ABSORBED CURRENT
- COS
φ
DETECTED
- OPERATING HOURS OF THE MOTOR
AUTOMATIC MOTOR
Cf 0.80 13.2 A
STOP MOTOR
Cf 1.00 0.0 A
400 V 13.2 A
Cf 0.80 0h
IT IS USED TO START
THE MOTOR MANUALLY
EXTERNAL COMMAND
OFF
EXTERNAL COMMAND
ON
OFF: DISABLE MOTOR
ON: ENABLE MOTOR
6.1
IF THE MOTHERBOARD DETECTS A
DRY RUNNING CONDITION IT WILL
BE POSSIBLE TO DISPLAY A FOURTH SCREEN
WAITING FILLING
START 1 h 10 m
IT DISPLAYS THE REMAINING
WAITING FILLING TIME
It is used to scroll through the pages
Pressed in MOTOR STOP status it starts the motor
in manual mode
Pressed it starts the motor in automatic mode
Pressed the motor goes in STOP function
Pressed in case of an alarm it resets it
35
IGNITION
CONTROL PANEL
ONLY IN STABLE MANUAL
BUTTON MODE
Summary of Contents for MULTIPLUS 1 SA684 Series