ENGLISH
5.2 Application cos
φ
MINIMUM COSFI
AUT. 0.68
MINIMUM COSFI
MAN. 0.68
MAN.
IT INDICATES THAT
THE COS
φ
VALUE HAS
BEEN SET MANUALLY
AUT.
INDICATES THAT THE COS VALUE
φ
HAS BEEN SET WITH AUTO-LEARNING
IT IS USED TO SET MANUALLY THE
COS
φ
VALUE UNDER WHICH
THE PUMP RUNS DRY
DRY RUN DELAY
4 s
DRY RUN DELAY
4 s
IT IS USED TO SET THE
INTERVENTION DELAY FOR
DRY RUNNING PROTECTION
RANGE 0.04 ÷ 0.99
RANGE 1 ÷ 10s
EXTERNAL COMMAND
1 INPUT
EXTERNAL COMMAND
1 INPUT
IN 1 INPUT MODE THE EXTERNAL COMMAND IS:
OFF
G.MIN
OPEN (DISABLE MOTOR)
ON
G.MIN CLOSED (ENABLE MOTOR)
EXTERNAL COMMAND
2 INPUTS
IN 2 INPUTS MODE THE EXTERNAL COMMAND IS:
OFF
G.MIN AND G.MAX CLOSED (DISABLE MOTOR)
ON
G.MIN AND G.MAX OPEN (ENABLE MOTOR)
EXTERNAL COMMAND
OFF
IN OFF MODE THE MOTHERBOARD
EXCLUDES THE CONTROL ON
THE EXTERNAL COMMAND
5.1
5. PROGRAMMING
29
THE MOTHERBOARD AUTOMATICALLY CALCULATES
THE WAITING FILLING TIME IN FUNCTION OF THE
WATER PRESENT IN THE WELL
IT IS USED TO SET A FILLING WAITING TIME WHICH INTERVENES EVERY TIME
THE MOTHERBOARD DETECTS A DRY RUNNING CONDITION
OFF
EXCLUDES THE
WAITING FILLING
RANGE 1min ÷ 99h 59min
THIS SCREEN
IS DISPLAYED ONLY IF
THE WAITING FILLING
IS SET TO AUTOMATIC
IT SERVES
TO RESET THE FILLING
WAITING TIME
WAITING FILLING
ENTER TO RESET
WAITING FILLING
RESET
WAITING FILLING
AUTOMATIC
WAITING FILLING
AUTOMATIC
WAITING FILLING
0 h 30 min
WAITING FILLING
OFF
PRESSING IT FOR MORE
THAN 1s YOU GO OUT
OF THE SETUP AND THE
PARAMETERS ARE
STORED IN THE MEMORY
PRESSED IT DISPLAYS
THE REMAINING PART
OF THE PARAMETERS
SEE CHAPTER 5.5