10. Functions explained
10. Functions explained
d05
dxx
d01
d02
d07
d08
d03
d04
Heating Control
Room temp. offset
Valve Protection
Frost Setpoint
OUT sensor probe (S1/S2)
Air sensor or Floor sensor
Cooling Control
0
-3.0oC to + 3.0oC
0/1
5ºC - 17ºC
0
0
1
2
1
1
1
2
PWM (Pulse-width modulation)
Offset room temp measuring error (in 0.5ºC)
0 = VP disabled 1 = Enable
Out sensor probe not connected
A: if d03 = 0, IN sensor controls Tr
ON-OFF: 0.5ºC (± 0.25ºC)
F: if d03 = 0, IN sensor controls Tr
A: if d03 = 1, IN disabled and OUT controls Tr
ON-OFF: 1.0ºC (± 0.5ºC)
F: if d03 = 1, IN disabled and OUT controls Tr Floor Protection
Out sensor probe connected
ON-OFF: 0.5C (± 0.25ºC)
ON-OFF: 1.0C (± 0.5ºC)
0
0.0ºC
1
5.0ºC
0
0
2
D setting function
Parameter/
Values
Default
value
Definition
22
AHTR5024 Instruction Manual
d00
Select oC/oF
0
1
Select oC
Select oF
0