background image

 

Wireless Radiant 
Thermostat 

AWRT10RF 

 

Quick Start Guide 

For other language versions, 

please visit www.salusinc.com 

Introduction 

The Wireless Radiant Thermostat (WRT) creates a comfortable room environment by 
accurately  controlling  your  radiant  heat  system.  Besides  the  intuitive  device 
interface, you can control the device from anywhere in the world when connected to 
the Salus Smart Home service via the Basic Gateway (sold separately) and the Salus 
Smart Home app for iOS and Android smartphones and tablets. 

Notices:   

Please read these instructions carefully 

before installing and using

 the 

Wireless Radiant Thermostat. 

 

Do not

 cover any of the vents on the thermostat. 

 

Do not

 place the unit in a bathroom or area of excessive moisture. 

 

Do  not

  allow  the  unit  to  get  wet.  This  device  serves  as  a  temperature  control 

system only in dry, closed living and office spaces. 

 

Do  not

  use  solvents  or  aggressive  cleaning  agents.  A  dry,  soft  cloth  is 

recommended.

 

The  manufacturer  does  not  accept  responsibility  for  any  damage  caused  by  not 
following these instructions. 

In the Box 

Make sure you have the following items: 

Tools Required: 

 

 

 

 

#1 Phillips or flathead 
screwdriver 

 

Drill with 3/16” bit 
(only if you need to use 
anchors)

 

Thermostat with 

Batteries and Wall Mount 

Screws and 

Anchors 

Quick Start 

Guide 

 

 

Keys 

 

(Left) 

(Up) 

(Right) 

 

(Settings) 

(Down) 

(SELECT) 

 

1.

 

Power Up Device 

Open  the  battery  compartment  on  the 
back  of  the  remote  and  pull  the  battery 
tab to power up the remote. Replace the 
batter cover when done. 

2.

 

Joining and Pairing the 
Thermostat 

After the initial boot up process, the WRT 
will  ask  what  type  of  device  it  will  be 
paired with. Use the ^ (Up) and v (Down) 
keys to select the device type. 

Once  the  device  type  is  selected,  the 
device will attempt to join a network, and 
if a network is joined, the device will then 
attempt  to  pair  with  a  device  of  the 
selected type. Additional selection criteria 
may be required depending on the device 
type. Below is a summary of the steps for 
each device type. 

Relay Controller 

- join network 
- scan for relay controller 

- ask for controller and zone to pair with 

- pair with controller and zone 
- go to Parameter Setup 
- go to home screen 

Radiator Valve 

- join network 
- pair with radiator valve actuators 
looking for thermostats 
- go to Parameter Setup 
- go to home screen 

Receiver 1 or 2 

- join network 
- pair with receiver if on network 
- go to Parameter Setup 
- go to home screen 

Press the Settings key at any time to cancel 
the  joining  or  pairing  activity  and  skip 
straight  to  the  Parameter  Setup  activity. 
Change the parameters by pressing ^ or v 
to  change  values  and  SELECT,  <  or  >  to 
move  through  the  parameters.  Confirm 
the changes by pressing Settings to go to 
the home screen. 

Once  the  parameters 

have  been 

confirmed, future power ups will skip the 
Parameter Setup  activity.  Parameters  can 
be  changed  by  going  to  the  Parameter 
Setup function in the Settings menu. 

3.

 

Decide on Location 

The  Wireless  Radiant  Thermostat  can  be 
mounted on a wall so that it is out of the 
way,  or  it  can  be  placed  in  a  desk  stand 
(sold 

separately) 

to 

control 

the 

temperature at a specific location. 

For  mounting  on 
a  wall,  remove 
the  Wall  Mount 
from  the  back  of 
the  remote  and 
attach  the  Wall 
Mount  to  the 
desired  location 
on the wall using 
the 

provided 

anchors and screws. 

Then  slip  the  thermostat  onto  the  Wall 
Mount until it latches. 

To  remove  the  thermostat  from  the  wall 
mount, use a small screwdriver to push the 
latch  at  the  top  of  the  wall  mount  to 
release  the  thermostat.  Then  lift  the 
thermostat from the wall mount. 

4.

 

External Sensor (optional)  

If  using  an  external  floor 
or 

air 

sensor 

(sold 

separately),  locate  the 
ends  of  the  sensor  wires 
and  insert  each  end  into 
one  of  the  terminals 
located  on  the  Wall 
Mount.  Using  a  Philips 

screwdriver,  rotate  the 
screws  clockwise  until 
the wires are snug. 

Then,  attach  the  Wall 
Mount  to  the  desired 
location  on  the  wall 
using  the  provided 
anchors  and  screws, 
and slip the thermostat 
onto the Wall Mount. 

NOTE: 

The Wireless Radiant Thermostat is 

intended  only  for  use  with  10k  NTC 
Thermistor sensors. 

To  complete the setup  of  the thermostat 
for  use  with  the  external  sensor,  set  the 
following parameters in Parameter Setup 
as appropriate: 

P15 EXT SENSOR = ON 
P16 XSNSR FNCT = FLR or AIR 

If operating as a floor (FLR) sensor, set the 
following trip points: 

P17 FLOOR TEMP MAX 
P18 FLOOR TEMP MIN 

5.

 

Normal Operation 

After  installation  and  setup  is  complete, 
the device will go to the Home Screen. The 
keys have the following  functions  on  the 
home screen. 

Key 

Function 

SELECT 

No function 

SETTINGS 

Enter/Exit  Settings  Mode 
for the following settings: 

 

C/F temperature units 
selection 

 

Set Clock and Calendar 
options 

 

Enter Change Schedule 
mode 

 

Enter Special Functions 
mode 

 

Initiate Identify mode 

< or > 
 

Move between Heat/Cool 
and OFF. 

(Cool is only available when 
paired with a relay controller 
and is selected by the relay 
controller)

 

^ or v 

Enter  Set  Point  Change 
mode if not OFF 

^ and v 

(hold for 5s)

 

Lock  or  Unlock  the  keys  if 
local locking is enabled. 

 

v 2 