12
II - 3 wire installation with KL08NSB wiring centre
3 wire installation with KL08NSB wiring center. Description of the operation rules:
- BTRP230V(50) thermostat’s functionality is limited because of 3 wire installation. NSB function is disabled and BTRP230V(50) thermostat doesn’t work
as a MASTER thermostat - no effect on other thermostats like BTR230V(20)
- schedules can be set individually on each BTRP230V(50) thermostats if system is equipped with more than one BTRP230V(50) thermostat
PLEASE NOTE!
The same operating rules apply to wiring center KL06.
THB23030
PUMP (optional)
T30NC230
BOILER
3 wires x 0.75 mm2
3 wir
es x
0.75
mm2
Power Supply
230V AC
Actuators wires
2 x 0.75 mm2
Pump control wires
2 x 1 mm2
Boiler control wires
2 x 1 mm2
KL08NSB
KL04NSB (optional)
BTRP230(50)
BTRP230(50)
BTRP230(50)
Summary of Contents for BTRP230V
Page 1: ...BTRP230V 50 THERMOSTAT FULL USER MANUAL...
Page 2: ......