24
3 sec.
If we are using this option then
d18 parameter should be set to „1”.
Move in settings using and
buttons. Confirm by button.
Hold button for 3 seconds to
enter the menu.
Then use button to choose
heating/cooling settings.
Confirm by button.
5.4 Heat/cool mode change
The heating / cooling mode for the thermostat
can be changed manually or automatically via
„CO” terminal. If 230V power is applied to the
„CO” terminal - then thermostat automatically
switches to cooling mode.
Set thermostat for heating using
and
buttons.
Confirm by button.
2
1
1
2
AUTOMATICALLY:
By external ON/OFF switch:
MANUALLY:
3
Wejście NSB
w regulatorze SLAVE
BTRP 230
KL08 NSB
L
S1
N
N
CO
L
SL
N
BTRP 230
Wyjście NSB
L
N
S1
N
CO
L
AC 230V
N
T30NC
/
NSB input in
SLAVE thermostat
NSB output
The heating / cooling mode for the thermostat can be changed manually or automatically via „CO” terminal. If 230V power is applied to the „CO” terminal
- then thermostat automatically switches to cooling mode. If you use this function in automatic mode, set the d18 parameter value to „1”.