Product Compliance & Safety Information

 

Product Compliance 

SALUS Controls hereby declares that the product complies with the essential 
requirements of the following EC Directives: 2014/30/EU, 2014/35/EU and 
2011/65/EU. The full text of the EU Declaration of Conformity is available at the 
following internet address: www.saluslegal.com. 

 

Safety Information 

Use in compliance with safety regulations. The unit is to be used for the control of 
room temperature inside the house.

 

Installation

 

This accessory must be fitted by a competent person, and installation must 
comply with the guidance, standards and regulations applicable to the city, 
country or state where the product is installed. Failure to comply with the relevant 
standards could lead to prosecution.

Note: 

All electrical installation work should be carried out by 

a suitable qualified electrician or other competent person.

Product Description

Thank you for purchasing the SALUS HTR230 Thermostat. This thermostat is a 
device that lets you customise the heating  and cooling of your home as needed. 

The HTR230 is an electronic room temperature controller which offers key 
advantages over conventional mechanical products.

The controller is easy to operate using the conventional backlit adjusting dial 
and offers you unique control convenience for heating applications of all types 
thanks to the high quality device electronics.

We hope you enjoy our product.

Contents of the box

Manual Contents:

Box Contents
Introduction
Product Compliance and 
Safety Information
Installation 
User Interface
Status/LED indication
Installers notes
Warranty

Icons used in this manual:

 

Safety

 

Important info

 

Your benefit

Fixing Screws

1 x Installer Manual

Dial Thermostat

Model: HTR230

INSTALLER MANUAL

SALUS C

ontr

ols plc

SALUS House

Dodw

orth Business P

ark S

outh,

Whinby R

oad,

Dodw

orth, Bar

nsley S75 3SP

, UK.

Sales:

 

T: +44 (0) 1226 323961

 

E: sales@salus-tech.com  

Technical:

 T

: +44 (0) 1226 323961

 

E: tech@salus-t

ech.com 

ww

w.salus-

con

trols

.com

SALUS C

ontr

ols is a member of the Computime Gr

oup

Maintaining a polic

y of continuous produc

t development SAL

US Contr

ols plc reser

ve the r

ight to 

change specification, design and mat

erials of pr

oducts list

ed in this brochur

e without prior notice

.

 

Issue Date: D

ec 2015 

00086/2

For PDF I

nstallation guide please 

go to w

ww

.salus-manuals.c

om

8. Technical Specification

Model:

HTR230

Voltage:

230 V AC, +-10%, 50/60 Hz

Operating Performance:

230 V: 1,8 W

Temperature setback: 

Temperature range: 

2°C-4°C

5°C- 30°C

Span: 

+/- 0,5°C

Calibration

:

Yes, with jumper

Storage temperature:

-20°C to +60°C

Ambient temperature:

0 °C up to 45 °C

Degree of protection

:

IP 30

CE conformity according to:

Class II ( EN60730 )

Housing material

:

PC, V2

Color:  

RAL 9010 pure white 

Connection: 

Screw terminal

Weight 

90g net / 135g gross

Puls-wide-modulation: 

(PWM)

Yes

Valve protection: 

Heating and Cooling:

Cooling blocked:

Dimensions: 

Yes

Yes, automatically Change Over on  the CO terminal

Yes, with jumper

85mm*85mm*25mm

Warranty

SALUS Controls warrants that this product (HTR230) will be free from any 
defect in materials or workmanship, and shall perform in accordance with 
its specification, for a period of five years from the date of installation. 
SALUS Controls sole liability for breach of this warranty will be (at its option) to repair 
or replace the defective product.

Customer Name: ......................................................................................................................................................

Customer Address: .................................................................................................................................................

............................................................................................................................................................................................

....................................................................................... Post Code: ...........................................................................

Tel No: .................................................................... Email: .......................................................................................

Engineers Company: ..........................................................................................................................................

Tel No: ...................................................................... Email: ....................................................................................

Instalation Date: ....................................................................................................................................................

Engineers Name: ...................................................................................................................................................

Engineers Signature: ...........................................................................................................................................

6. Protection Function

7. Control Patterns

5. Thermostat Functions

NSB (Night SetBack) Function

NSB Mode depends on the NSB wired connection. 

 

0V =   NSB OFF

24V=  NSB ON

The NSB signal is activated every 1 second. When the signal is received the 
setpoint temperature will be set at 

±

2°C or 

±

4°C.

Heating and Cooling Selection

The Heating/Cooling function is determined by the CO terminal connection.

CO 0V=    Heat mode 
CO 24V=    Cool mode

Cooling Blocked function

Cooling Enabled:
Set the jumper on ON                   . The thermostat will run in normal cooling mode. 
That means that it will open/close the actuators when necessary. The LED will be 
BLUE when the cooling function is running.

Cooling Disabled:
Set the jumper on OFF                .  The actuator will be closed and the LED will 
be off.

Heat cut off at high/low temperature:

When room temperature is over 36°C or under 4°C, all heating/cooling outputs 
will be turned off.

Short cycle protection:

When Cooling Mode is enabled the minimum interval between Relay ON/OFF 
is 3 minutes.

Valve Protection:

Set the jumper on ON to disable the function or on OFF to enable it. Turn on the 
valve for 5 minutes every week to prevent the valve any damages on the valve.

Sensor Malfunction:

If the temperature sensor or temperature sensor compensation is open the LED 
will flash BLUE/RED alternatively.

If CO terminal is connected and the Heating Mode is ON, the PWM function 
will be activated.

If CO terminal is disconnected and the Cooling Mode is ON the ON/OFF control 
output will be activated.

HTR230 Thermostat

Gently remove front housing and 
make the wiring connections.

2. Terminal Connection

4. Jumpers

1. Mounting the Thermostat

3. Switching Bridges

Note: You can wire the thermostat 
directly to the KL08NSB Wiring 
Center (purchased separately).

Wall mounting

For wall mounting, mark the correct 

possition on the wall and mount the 

rear case to the wall.

Install the HTR230 dial room thermostat at roughly 1.5m above floor level. It 
should be mounted in a location where the thermostat is easily accessible and 
away from direct sunlight.

CO

N

L

ACTUATOR

30ºC

25

N

L

E.G.

HEAT

PUMP

EXTERNAL

CLOCK

230VAC

50Hz

CO

N

L

30ºC

25

Different features of the HTR230 
can be switched On or OFF with 
the jumpers. In order to do this 
please follow the table below.

 

HTR 230 Switching Bridges

Switch

VP

Valve protection feature

Pulse-Width-Modulation

NSB Function (2° or 4°)

Heating/Cooling

PWM

CO

Feature

ON

OFF

2°C

Enable

Disable

4°C

The jumpers from 1 to 5 are representing the number of actuators that you can connect 
to the thermostat.

After the actuators are mounted please move the jumper on the correct number (the 
same as the number of actuators).

Depending on the amount of actuator used, please change the jumper position 
accordingly to compensate the power consumption.

Reviews: