background image

Product compliance

Safety Information

Box content

This product complies with the essential requirements and other relevant provisions of the following EU 
Directives: 2014/30/EU, 2014/35/EU and 2011/65/EU. Please check  www.saluslegal.com for the full information.

Use in accordance with the EU and national regulations. For indoor use only. Keep your device completely 
dry. This product must be installed by a competent person and in accordance with all the EU and national 
regulations.

Always isolate the AC Mains supply before installing or working on any components that 

require 230 VAC 50Hz supply.

The box includes the EP110 controller, 2X screws and plugs and the Quick Guide installation manual. 

Backlight/

Holiday

Mode

+1Hr

Down

Up

Select

Set

Reset

Installer Manual-Quick Guide

Always isolate the AC Mains supply before installing or working on any components 

that require 230 VAC 50Hz supply.

Introduction

A programmable controller is used to switch the heating system and/or 
the hot water in your home on and off as needed. It works by controlling 
the central heating and/or the hot water with  programmed settings that 
take effect at different times of the day.

Go to www.salus-manuals.com for the full PDF version of the manual.

Product Compliance

EU Directives: 2014/30/EU, 2014/35/EU and 2011/65/EU. Please check  
www.saluslegal.com for the full information.

Safety Information

Use in accordance with the EU and national regulations.
For indoor use only.
Keep your device completely dry.
This product must be installed by a competent person and in accordance 
with all the EU and national regulations.

Difference between EP110/EP210/EP310

Installation

Jumper Settings

First Power Up

Button Function

The EP line will offer you the possibility to customize your central heating system 
and hot water system as desired.

EP110 is recommended for users that want to control only the Central Heating or 
the Hot Water system.

EP210 is designed to give you a full control with only one device of both your 
Central Heating and Hot Water system.

EP310 is the most versatile product of this line and lets you manage two different 
Central Heating zones and the Hot Water with only one controller.

Model: EP110/EP210/EP310

Input:      230V, 50Hz
Output:   3A/ switch terminal

1

2

3

EP110 Volt Free application only

EP210 - 230V Application

EP310 - 230V Application

EP110 - 230V Application Only

Note

:  Please remove  red link wire for this application.

 Terminal 

Description 

Backplate

 

Mains Neutral

 

Mains Live

 

Not Used

 

Not Used

 

Volt Free Connection

 

Volt Free Connection 

  

Earth Parking

  

(no electrical connection)

N L 1 2 3 4

N L 1 2 3 4 5 6

 Terminal 

Description 

Backplate

 

Mains Neutral

 

Mains Live

 

NC (Output)

 

Not Used

 

Switch Live (Output)

 

230V Common (via Link)

  

Earth Parking

  

(no electrical connection)

N L 1 2 3 4

N L 1 2 3 4 5 6

 Terminal 

Description 

Backplate

 

Mains Neutral

 

Mains Live

 

Hot Water Off

 

Central Heating Off

 

Hot Water On

 

Central Heating On

  

Earth Parking

  

(no electrical connection)

N L 1 2 3 4

N L 1 2 3 4 5 6

 Terminal 

Description 

Backplate

 

Mains Neutral

 

Mains Live

 

Hot Water Off

 

Central Heating Off

 

Hot Water On

 

Central Heating 1 On 

 

Central Heating 2 On 

 

Central Heating 2 Off

  

Earth Parking

  

(no electrical connection)

N L 1 2 3 4

N L 1 2 3 4 5 6

Changes to the jumpers settings should only be made by the Engineer carrying 
out the installation or other qualified person. The installer should select the jumper 
positions required if changes need to be made to the factory default settings. 
These jumpers are found on the rear of the controller. 

* P - Fully pumped system for independent Central Heating and Hot Water.
* G - Gravity Hot Water system with Pumped Central Heating.

EP110/ EP210/ EP310 Switching Bridges

Switch

Program

5-2 days programme or

24h programme

Fully pumped system(P*)

or gravity-fed hot water 

system(G*)

Disable/enable the internal 

backup battery

System

Feature

EP110/310 Settings

Memory 

Backup

5-2

24H

24H

5-2

NA

NA

P

G

OFF

ON

OFF

ON

EP210 Settings

EP110/EP310

EP210

EP110

EP310

EP210

1. Turn on the LCD backlight

2. Press for 3 sec to activate Holiday mode

Select operating mode (ON, ONCE, AUTO, ADV, OFF)

Activate/deactivate Boost function

Decreases the selected setting

Increases the selected setting

Select a clock or programme setting

Sets a clock or programme setting

Reset to Factory settings

EP110

CH or HW

EP210

CH and HW

EP310

2x CH and 1x HW

MODE

SELECT

SET

+HR

EP110 Controller

2x screws and plugs

Quick Guide Installation

EP110 Installation Manual      03

Summary of Contents for EP110

Page 1: ...Installation Manual Model EP110 Single channel programmable controller...

Page 2: ...Safety Information 3 Box content 3 Introduction 4 Features 4 Installation 5 Button functions and LCD icons 7 Operations 8 Functions 14 Factory Reset 16 Technical Info 17 Warranty 18 Contents 02 EP110...

Page 3: ...4 35 EU and 2011 65 EU Please check www saluslegal com for the full information Safety Information Use in accordance with the EU and national regulations Installation Jumper Settings First Power Up Mo...

Page 4: ...in a fully pumped and controlled system where heating and hot water can be operated independently or in gravity fed water system where the central heating cannot be operated without hot water The heat...

Page 5: ...1 2 3 4 5 6 Wiring and terminal description Terminal Description Backplate N Mains Neutral L Mains Live 1 Not Used 2 Not Used 3 Volt Free Connection 4 Volt Free Connection Earth Parking no electrical...

Page 6: ...ngineer carrying out the installation or another qualified person The installer should select the jumper positions required if changes need to be made to the factory default settings These jumpers are...

Page 7: ...ter fast advance Press to activate backlight Hardware reset Press and hold button for 3 seconds to activate Holiday mode Select Set Press and hold buttons to enter clock setting mode Showing when rela...

Page 8: ...he software version is shown and after that the typical reset display is shown The time should be 12 00am Default settings Function Status after Reset Operation Mode Normal mode Clock 12 00 AM AM PM i...

Page 9: ...rm When Daylight saving time is enabled the clock will automatically change from Greenwich Mean Time GMT to British Summer Time BST on the last Sunday in March The clock will automatically change back...

Page 10: ...ram When the ADV function ends the device will return to normal program OFF Continuously off Operating Modes MODE Hr SELECT SET For activating the functions described above press the MODE button The o...

Page 11: ...as 08 00 ON 09 00 OFF 10 00 ON 11 00 OFF Selecting ADV between 8 00 and 8 59 will change the output to OFF from 9 00 onwards back to AUTO which is also OFF Selecting ADV between 9 00 and 09 59 will ch...

Page 12: ...SELECT SET Press Set to start programming MODE Hr SELECT SET Press Up or Down to set the minutes Press Select to confirm MODE Hr SELECT SET Press Up or Down to set end time for prog 1 Press Select to...

Page 13: ...Down to set the minutes Press Select to confirm MODE Hr SELECT SET Press Up or Down to set end time for prog 1 Press Select to confirm MODE Hr SELECT SET Press Up or Down to set the minutes Press Sele...

Page 14: ...ivated even in ADV mode When boost mode is activated ADV is canceled Press 1Hr at current mode to activate the Boost Override 1Hr override setting mode Boost mode increases the time of the active prog...

Page 15: ...p to 31 To exit Holiday Override and turn On the relay long press the key MODE Hr SELECT SET MODE Hr SELECT SET Press Up Down keys to select days Enter Holiday Mode Exit Holiday Mode MODE Hr SELECT SE...

Page 16: ...ess the Reset button once use a pin for this action MODE Hr SELECT SET MODE Hr SELECT SET MODE Hr SELECT SET Press reset button LCD will turn OFF All icons will be displayed Software version Normal Mo...

Page 17: ...0 non condensing Storage Temperature Humidity 20 C 60 C 10 90 non condensing Programs Program 5 2 or 24hr individual program selectable by jumper 3 settings day with holiday override Boost Override Ye...

Page 18: ...cification for a period of two years from the date of installation SALUS Controls sole liability for breach of this warranty will be at its option to repair or replace the defective product Customer N...

Page 19: ...tech salus tech com www salus controls com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserves the right to change spec...

Reviews: