background image

Backlight/

Holiday

Mode

+1Hr

Down

Up

Select

Set

Reset

Installer Manual-Quick Guide

Always isolate the AC Mains supply before installing or working on any components 

that require 230 VAC 50Hz supply.

Introduction

A programmable controller is used to switch the heating system and/or 
the hot water in your home on and off as needed. It works by controlling 
the central heating and/or the hot water with  programmed settings that 
take effect at different times of the day.

Go to www.salus-manuals.com for the full PDF version of the manual.

Product Compliance

EU Directives: 2014/30/EU, 2014/35/EU and 2011/65/EU. Please check  
www.saluslegal.com for the full information.

Safety Information

Use in accordance with the EU and national regulations.
For indoor use only.
Keep your device completely dry.
This product must be installed by a competent person and in accordance 
with all the EU and national regulations.

Difference between EP110/EP210/EP310

Installation

Jumper Settings

First Power Up

Button Function

The EP line will offer you the possibility to customize your central heating system 
and hot water system as desired.

EP110 is recommended for users that want to control only the Central Heating or 
the Hot Water system.

EP210 is designed to give you a full control with only one device of both your 
Central Heating and Hot Water system.

EP310 is the most versatile product of this line and lets you manage two different 
Central Heating zones and the Hot Water with only one controller.

Model: EP110/EP210/EP310

Input:      230V, 50Hz
Output:   3A/ switch terminal

1

2

3

EP110 Volt Free application only

EP210 - 230V Application

EP310 - 230V Application

EP110 - 230V Application Only

Note

:  Please remove  red link wire for this application.

 Terminal 

Description 

Backplate

Mains Neutral

Mains Live

Not Used

Not Used

Volt Free Connection

Volt Free Connection 

Earth Parking
(no electrical connection)

N L 1 2 3 4

N L 1 2 3 4 5 6

 Terminal 

Description 

Backplate

Mains Neutral

Mains Live

NC (Output)

Not Used

Switch Live (Output)

230V Common (via Link)

Earth Parking
(no electrical connection)

N L 1 2 3 4

N L 1 2 3 4 5 6

 Terminal 

Description 

Backplate

Mains Neutral

Mains Live

Hot Water Off

Central Heating Off

Hot Water On

Central Heating On
Earth Parking
(no electrical connection)

N L 1 2 3 4

N L 1 2 3 4 5 6

 Terminal 

Description 

Backplate

Mains Neutral

Mains Live

Hot Water Off

Central Heating Off

Hot Water On

Central Heating 1 On 

Central Heating 2 On 

Central Heating 2 Off
Earth Parking
(no electrical connection)

N L 1 2 3 4

N L 1 2 3 4 5 6

Changes to the jumpers settings should only be made by the Engineer carrying 
out the installation or other qualified person. The installer should select the jumper 
positions required if changes need to be made to the factory default settings. 
These jumpers are found on the rear of the controller. 

* P - Fully pumped system for independent Central Heating and Hot Water.
* G - Gravity Hot Water system with Pumped Central Heating.

EP110/ EP210/ EP310 Switching Bridges

Switch

Program

5-2 days programme or

24h programme

Fully pumped system(P*)

or gravity-fed hot water 

system(G*)

Disable/enable the internal 

backup battery

System

Feature

EP110/310 Settings

Memory 

Backup

5-2

24H

24H

5-2

NA

NA

P

G

OFF

ON

OFF

ON

EP210 Settings

EP110/EP310

EP210

EP110

EP310

EP210

1. Turn on the LCD backlight

2. Press for 3 sec to activate Holiday mode

Select operating mode (ON, ONCE, AUTO, ADV, OFF)

Activate/deactivate Boost function

Decreases the selected setting

Increases the selected setting

Select a clock or programme setting

Sets a clock or programme setting

Reset to Factory settings

EP110

CH or HW

EP210

CH and HW

EP310

2x CH and 1x HW

MODE

SELECT

SET

+HR

Reviews: