Page 2: ...duct Compliance 4 Safety Information 4 Box content 4 Features 5 Installation 5 Button functions 7 LCD icons 8 Operations 9 Functions 18 Factory Reset 21 Technical Info 22 Warranty 23 Contents 02 EP210 Installation Manual ...

Page 3: ...gs per day Being a complex programmable controller the EP210 gives you the possibility to override your programs by using the Boost function This can be enabled for up to 9 hours For the periods when you are away you can use the Holiday function which will turn off the relay The Holiday Mode can be set for a period of maximum 31 days When connected to a system with a non programmable digital therm...

Page 4: ...EU and 2011 65 EU Please check www saluslegal com for the full information Safety Information Use in accordance with the EU and national regulations For indoor use only Installation Jumper Settings First Power Up Model EP110 EP210 EP310 Input 230V 50Hz Output 3A switch terminal 1 2 EP110 Volt Free application only EP210 230V Application EP110 230V Application Only Note Please remove red link wire ...

Page 5: ...entral Heating On Earth Parking no electrical connection N L 1 2 3 4 N L 1 2 3 4 Features Dual Channel Programmer for Central Heater or Hot Water 12 or 24 hour clock format 5 2 or 24 h individual programs with 3 settings per day Boost function Holiday function Advance function Memory backup N L 1 2 3 4 N L HW CH HW CH off off on on EP210 Installation Manual 05 ...

Page 6: ...ry disabled Note Changes to the jumper setting should only be made by the engineer carrying out the installation or another qualified person The installer should select the jumper positions required if changes need to be made to the factory default settings These jumpers are found on the rear of the controller The jumpers are found on the rear of your controller and can be used to change the setti...

Page 7: ... setting of clock date week day etc Set Press to confirm the setting Up arrow Press to increase clock day press and hold to enter fast advance Down arrow Press to decrease clock day press and hold to enter fast advance Press to activate backlight Hardware reset Press and hold button for 3 seconds to activate Holiday mode Select Set Press and hold buttons to enter clock setting mode MODE MODE Hr Hr...

Page 8: ...heating Holiday Mode Boost hours for hot water AM PM 1 2 3 4 5 6 7 Days of the week 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 OFF Mode ADV Mode On AUTO Mode On ONCE Mode On On Mode DST On Off 8 9 10 11 12 13 14 Hot Water On 15 Program number 08 EP210 Installation Manual ...

Page 9: ... version is shown and after that the typical reset display is shown The time should be 12 00am Default settings MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET Function Status after Reset Operation Mode Normal mode Clock 12 00 AM AM PM indicator AM Date January 1 2016 Daylight Saving Time DST On Program Factory default 5 2 Program Number indicator Off SET indicator...

Page 10: ...r controller First you will need to set up the time and then the date To enter clock setting mode press and hold Select and Set buttons for 3 seconds Please follow the instructions below Press Select to confirm MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET Press Select to confirm MODE MODE Hr Hr SELECT SET Press Select to confirm MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET MODE M...

Page 11: ...On for 1 period a day from Program 1 ON to Program 3 OFF AUTO Automatic program control ADV When device is in Auto or Once mode press the MODE button for 3 sec for selecting Advance ADV This will move the unit into the next program When the ADV function ends the device will return to normal program OFF Continuously off Operating Modes For activating the functions described above press the MODE but...

Page 12: ...n ONCE mode the controller gives the boiler the command to run only for one period per day from program 1 ON to program 3 OFF MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET Press for CH mode Press for HW mode MODE MODE Hr Hr SELECT SET Press for CH mode Press for HW mode ONCE Mode Auto Mode Press for CH mode Press for HW mode Pressing the Mode key 3 times activates the AUTO In AUTO mode the...

Page 13: ...tput to ON from 10 00 onwards back to AUTO which is also ON If the ADV puts the relay ON then the boost would apply immediately at the next OFF change if the ADV put the relay OFF then the boost would apply immediately and turn the relay ON 08 00 OFF 10 00 ON 12 00 OFF 14 00 ON If ADV occurs at 08 30 and the relay is ON from 08 30 to 12 00 During this period if at 08 45 1Hr Boost is pressed the re...

Page 14: ...ou can program the schedules for these outputs individually or together When you program them together there will be the same program time for both Heating and Hot Water If you choose to program them individually you can have different program times for each 5 2 Program MODE MODE Hr Hr SELECT SET Press Set to enter setting programs MODE MODE Hr Hr SELECT SET The CH icon and Mon Fr will start flash...

Page 15: ...HW individually goes at it follows Weekday CH program 1 3 Weekday HW program 1 3 Weekend CH program 1 3 Weekend HW program 1 3 and all over again Note To save your settings and exist to home screen in normal mode press Set at any time Programming CH and HW together The programming principle is exactly the same but you can only set the same Start End time for the CH and HW The programming sequence ...

Page 16: ...r SELECT SET The CH icon will go steady the program number will appear and you will need to select a start time for the CH program Use up down arrows Programming CH and HW individually 6 MODE MODE Hr Hr SELECT SET 6 Press Select MODE MODE Hr Hr SELECT SET Use up down arrows to select minutes 6 MODE MODE Hr Hr SELECT SET 6 Press Select 6 MODE MODE Hr Hr SELECT SET 8 Press Select MODE MODE Hr Hr SEL...

Page 17: ...esday HW program 1 3 Wednesday CH program 1 3 Wednesday HW program 1 3 etc Note To save your settings and exist to home screen in normal mode press Set at any time Programming CH and HW together MODE MODE Hr Hr SELECT SET Press Set to enter setting programs MODE MODE Hr Hr SELECT SET The CH icon and Mon will start flashing Press up arrow 2 times MODE MODE Hr Hr SELECT SET Press Select to start ent...

Page 18: ...f the number rolls back to blank this will disable the Boost Override Press 1Hr to enter Boost override The number of boost hours will be displayed To exit boost override press mode button until number x disappears MODE MODE Hr Hr SELECT SET Boost Override 1Hr override for Heating MODE MODE Hr Hr SELECT SET 1 MODE MODE Hr Hr SELECT SET Press 1Hr to enter Boost override The number of boost hours wi...

Page 19: ...r override Boost is running then ADV is selected ADV will be activated and the previous 1Hr override will be canceled Long press Mode while in Auto or Once to enter ADV override Mode Short press Mode while in ADV to exit mode back to auto or Once ADV Override for Heating ADV Override for Hot Water MODE MODE Hr Hr SELECT SET Long press Mode while in Auto or Once to enter ADV override Mode Short pre...

Page 20: ... be to set the number of holiday days up to 31 To exit Holiday Override and turn On the relay long press the key Press Up Down keys to select days Enter Holiday Mode Exit Holiday Mode Press for 3 seconds Press for 3 seconds Controller in current mode LCD Backlight If AC is powered LCD backlight is activated when or any key is pressed The backlight will be turned off in 15 seconds after all keys ar...

Page 21: ...n once use a pin for this action Press reset button LCD will turn OFF All icons will be displayed Software version MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET MODE MODE Hr Hr SELECT SET Normal Mode MODE MODE Hr Hr SELECT SET EP210 Installation Manual 21 ...

Page 22: ...0 non condensing Storage Temperature Humidity 20 C 60 C 10 90 non condensing Programs Program 5 2 or 24hr individual program selectable by jumper 3 settings day with holiday override Boost Override Yes max 9 hours selectable by software Holiday Override Yes max 31 days selectable by software Clock Clock Format 12 or 24 hour selectable by software Clock Accuracy 1 min month Daylight Saving Time DST...

Page 23: ...ecification for a period of two years from the date of installation SALUS Controls sole liability for breach of this warranty will be at its option to repair or replace the defective product Customer Name Customer Address Post Code Tel No Email Company Name Tel No Email Installation Date Installer Name Installer Signature EP210 Installation Manual 23 ...

Page 24: ... tech salus tech com www salus controls com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserves the right to change specification design and materials of products listed in this brochure without prior notice For the latest PFD Instruction Manual go to www salus manuals com Issue Date April 2017 V001 ...