Introduction

Terminals description

Electrical diagram

DIN rail mounting

Display description and button functions

Product Compliance

Control module for FC600 thermostat 

Model: 

FC600-M 0-10V

Safety Information

Principle of operation

The FC600-M 0-10V module is dedicated to fan coils or trench heaters con-

trolled  by 0 ... 10V signal. It is a supplement to the main thermostat SALUS 

FC600. The module smoothly adjust fan speed via controling 0V...10V 

voltage. In addition, device can control two electric actuators (heating 

and cooling valve).

This product complies with essential requirements of the European 

Parliament Directive And Of The Council 2012/19 / EU of 4 July 2012 on 

waste electrical and electronic equipment (WEEE).

230V AC

2-PIPE SYSTEM

4-PIPE SYSTEM

OR

Po

w

er supply unit (PSU) 230V A

C / 24V DC

1.  

  Double-digit, 7-segment LED display

        - displays parameters: F1, F1, F3, t and voltage and time values

2. 

   Entering the menu, selecting the parameter, increasing the value

3. 

   Confirmation of parameter selection, reduce the value

Use in accordance with national and local regulations of the country and 

in EU territory. 

Indoor use only. Keep your equipment completely dry. 

The installation must be carried out by a qualified person in accordance 

with the rules of the country and in the EU.

Before install, repair, maintenance or during any connection work 

disconnect power supply from the module and make sure the terminals 

and wires are free of voltage.

The electrical installation where module works should be secured with  

a fuse, specially selected to the applied loads.

The device can not be used with the damaged case.

Under no circumstances dont’t modify the module construction.

Do not allow access to the module to people who didn’t read this manual. 

Do not install the device under voltage.

A short circuit at the output may damage the unit.

It is forbidden to operate a defective device or repaired by unauthorized 

service.

For module covering there is a special installation enclosure for the 
installation of electrical equipment. This enclosure should prevent user 
before access to the module wiring terminals. The module is designed to 
be mounted on a standard 35mm DIN rail. Before sliding the module             . 
onto the DIN rail          , slide the hook          using the flat screwdriver. When 
module is mounted on the rail, place the hooks at the original position. 
Make sure that module is mounted solidly and that it can not be removed 
from the rail without a tool.

NOTE:

 The connection wires should be protected against tearing, 

loosening, or built up in such a way that they can not be exposed to 
mechanical stress.

The module recognizes input signals from SALUS FC600 for three different 

voltage fan levels and accordingly sets the 0V...10V output voltage. 

Voltage values   for each levels and time of voltage incrase on output are 

settable by buttons and displayed on LCD.  Settings are saved to the device 

memory. The module smoothly changes the voltage value at startup and 

during switching between fan speed mode. 

Additionally this module recognizes the input signals for the heating valve 

and a cooling valve. Accordingly which signal will be received, module will 

send +24V voltage at the output for the heating/cooling valve.

Terminal

Name

Function

Module power supply 24V DC

Heating valve control output

Cooling valve control output

Power supply and fan control 24V DC

F1

Fan Speed control (Low level) - 230V AC input

F2

Fan Speed control (Medium level) - 230V AC input

F3

Fan Speed control (High level) - 230V AC input

V1

4 pipe: 230V AC control input - heating valve
2 pipe: 230V AC control input - heating / cooling valve

V2

4 pipe: 230V AC control input - cooling valve
2 pipe: N/A

N

Neutral

1

1

2

3

2

3

1

3

2

Instructions Manual

www.salus-controls.eu

SALUS Controls is a member of the Computime Group

Maintaining a policy of continuous product development SALUS Controls plc reserve 
the right to change specification, design and materials of products listed in this brochure 
without prior notice.

Issue Date: VII 2017

Distributor of SALUS Controls:

QL CONTROLS Sp. z o.o., Sp. k.
Rolna 4 
43-262 Kobielice,
Poland
salus@salus-controls.pl

Reviews: