background image

32         Fan Coil FC600 Instruction Manual

If you have an occupancy sensor connected to your S2 terminal, for example a hotel card, it will also show 
on the App. When the card will be inserted, meaning man in room, the icon will be displayed on your screen. 
Otherwise, an empty door will show. The user can define if thermostat should go to ECO mode or STANDBY 
mode when there is nobody in the room, by changing the parameter d34 in Installer Menu.

Man in room.

Empty room - thermostat in 

Eco Mode.

The window sensor associated with the thermostat will allow you to create certain rules when the window is 
closed/open. If the information about an open/closed window is received during one of the programs (when 
the thermostat is following a schedule), than the rule will be applied until the next program starts. Also, you 
can chose that the thermostat will follow the previous mode after the window is closed. In order to have this 
function available, you need to have window sensor added to your system and add it to the thermostat. Please 
see below.
To add a window sensor to you system, please refer to OS600 manual on salus-manuals.com

3.10 Window Association Function

3.9 Occupancy Sensor

Tap window icon.

Tap window icon.

Select the option and the 

associated sensor. 

Tap OK to save your 

settings.

Summary of Contents for FC600

Page 1: ...1 Fan Coil FC600 Instruction Manual Instructions Manual Fan Coil thermostat Model FC600...

Page 2: ...2 Fan Coil FC600 Instruction Manual Page intentionally left blank...

Page 3: ...der 20 2 9 4 Error Codes 20 2 10 STANDBY Mode 21 3 Operation Manual Online Mode 22 3 1 Quick Overview 22 3 2 App screen Icon Description 23 3 3 Device name change 24 3 4 Temperature Setpoint 24 3 4 He...

Page 4: ...offline Mode with no Internet connection 50 4 7 2 Switching from non programmable to programmable thermostat 50 4 7 Installer Parameters 50 4 7 3 In online Mode via App 51 4 8 Full Parameter List 51...

Page 5: ...a weeklyordailybasis depending on your preferences and needs It has multiple work configuration possibilities and can be controlled in both off line and on line modes Besides that it can work in Eco M...

Page 6: ...gh in order to maintain the room temperature Digital Programmable Short press Long press 2 sec Increase Function Key Decrease Mode button Fan Speed Low Medium High Auto Off Short press Confirm functio...

Page 7: ...ow medium high Auto OFF 6 Wireless communication icon 7 Glob icon 8 Temperature unit 9 Heating Mode ON 10 Cooling Mode ON 11 STANDBY mode 12 Occupancy vacancy sensor 13 Lock function 14 AM PM 15 Eco M...

Page 8: ...to the Universal Gateway 19 Sensor indicators This icon is visible when a sensor is connected to S1 Com or S2 COM terminals 7 Glob icon This icon is appears when the thermostat is connected to the Uni...

Page 9: ...oint temperature is the temperature you want to set or the temperature set by the program Under your home display press or to view the set point temperature When the program is running after the short...

Page 10: ...Button during Temporary Override it will get canceled and the thermostat will enter previous mode M Note If you are using the Mode Button please make sure that thermostat is following the appropriate...

Page 11: ...he current temperature and the Fan Coil will maintain it until you set a new setpoint If you have Manual Heat Cool selection these are the 4 possible combinations you can have by short pressing the Mo...

Page 12: ...sensor then the Eco Mode will be activated automatically when the set up is complete This is the default setting You can choose from either ECO or STANDBY mode when depending on the position of the ke...

Page 13: ...s in Eco Mode The snowflake icon indicates that the thermostat is in Cooling Mode When in Eco Mode the thermostat will use Eco setpoint to control room temperature You cannot change the temperature in...

Page 14: ...ng on the auto heat cool changeover setpoint temperature Eco Mode with auto heat cool changeover The temperature will be set using Eco temperature setpoint You cannot change the setpoint in Eco Mode B...

Page 15: ...eset thermostat will go to home screen After you have completed time and date setup you can start setting up your schedules and programs M 05 01 Press OK Note If your thermostat is non programmable it...

Page 16: ...l heat cool changeover you will need to select for which mode you want to set a schedule If you have Auto heat cool changeover the device will skip steps 3 4 M PressModebuttonfor3seconds Press UP arro...

Page 17: ...amming all week the same you will have to set all the 6 programs just once M 1 06 00 Press OK to confirm M 1 06 00 Press Up Down arrows to set the minutes M 1 06 00 Press OK to confirm M 1 06 00 Set a...

Page 18: ...g of Tuesday then Wednesday Thursday Friday Saturday and Sunday finally exit the program setting mode Long press or is only to change fast time and temperature At any time of setting long press to ret...

Page 19: ...3 0 C in 0 5 C steps This is handy if your thermostat is located in a spot with a slightly different temperature than the overall room temperature You can access the offset also by pressing the Mode b...

Page 20: ...cuit 03 External sensor open or external sensor is not connected 04 External sensor short circuit When the external sensor is reconnected or fixed thermostat will return to Normal mode and display the...

Page 21: ...our thermostat You can always switch back off STANDBY Mode by long pressing the OK button All relay outputs immediately change to OFF regardless of the previous operating mode heat cool auto heat cool...

Page 22: ...om and the possibility to manage the temperature in your house office remotely Thermostat tile on the App Thermostat tile when tapped Thermostat interface 3 1 Quick Overview The functions available on...

Page 23: ...ting Cooling On Off Schedule Eco Hold Tap for submenu Fan Speed Off On Tap for submenu Lock Unlock thermostat Pin Unpin thermostat to dashboard Settings Button Window sensor button Find your device Me...

Page 24: ...temperature and to the right will increase If your thermostat is on permanent hold it will follow the setpoint temperature until you manually change it again That is permanent override if the thermos...

Page 25: ...value If you want to set a temperature that is lower than the current temperature in the room you need to choose Cool Mode before changing the Set point to the new value Otherwise the thermostat will...

Page 26: ...rride mode the user manually changed the temperature during the program the hand and the calendar icon will be displayed together When in temporary override the thermostat will return back to followin...

Page 27: ...at exists Eco Mode it returns to the previous set mode Eco set point setting parameter is d10 for heating mode and d11 for cooling mode The default set point temperature is 30 C for cooling mode and 1...

Page 28: ...orking in Frost Protection When the thermostat is running in STANDBY Mode you cannot change the temperature set point or control the operations in any way Please follow the steps below Note After the...

Page 29: ...ll appear on your screen Go to your thermostat scroll down and tap on pen Click on arrow and a drop down menu with days options will be displayed You can choose Mon Fri Sat Sun program 5 2 All 7 days...

Page 30: ...he programs on the thermostat in any way you want Note If you selected Heating or Cooling ONLY in your initial setup only ONE field Heating or Cooling will be displayed and only that one will require...

Page 31: ...by the TPI method TPI is a learning algorithm for the fan It tells the fan in which speed it has to run in order to be most economy efficient Not that it only sets the speed depending on the differenc...

Page 32: ...llow you to create certain rules when the window is closed open If the information about an open closed window is received during one of the programs when the thermostat is following a schedule than t...

Page 33: ...ring 10 minutes Tap it again to stop identification mode M 3 11 Identification Function 3 12 Pin Unpin thermostat to the dashboard Thermostat is pinned to the dashboard Tap pin to unpin Tile is visibl...

Page 34: ...u to change settings on your thermostat You will have to enter a special password in order to access the settings menu Please read more in the Installer Manual section about more detail on how to acce...

Page 35: ...mfort temperature Set thermostat to 21 C Run frost mode Set thermostat to frost mode To activate a pre existing OneTouch please follow the steps below For example you want to set the Party Mode OneTou...

Page 36: ...ll mounting 4 1 Box Contents The ideal position to locate the FC600 thermostat is about 1 5m above floor level in a location where the thermostat is accessible reasonably lit and free from extremes of...

Page 37: ...il FC600 Instruction Manual 4 2 Idea diagrams Below you can find some possible usage diagrams for the Fan Coil thermostat depending on the on your system and components 2 pipe heating only 2 pipe cool...

Page 38: ...38 Fan Coil FC600 Instruction Manual 2 pipe heating OR cooling 2 pipe heating AND cooling...

Page 39: ...occupancy sensor launching ECO or Standby mode Pipe temperature sensor allows the fan to be working or not Air temperature sensor or external room temp sensor FC600 will display temperature from the...

Page 40: ...ensor launching eco mode Air temperature sensor or external room temp sensor activeT2 sensor disable temperature measurement in thermostat Pipe temperature sensor allows fan to work only in 2 pipe sys...

Page 41: ...is connected and it is deciding in what mode the thermostat should be working In 4 pipe system S1 Auto it means nothing is connected to S1 COM and thermostat is measuring the room temperature to selec...

Page 42: ...nsor i e the water temperature inside the pipe is used to change over from heating to cooling mode or vice versa When the pipe temperature is above e g 30 C parameter d25 the thermostat changes over t...

Page 43: ...can go to ECO mode or STANDBY mode defined by d34 parameter Occupancy sensor can be used in 2 pipe or 4 pipe applications External Temperature Sensor External Temperature Sensor External Temperature...

Page 44: ...Fan Coil FC600 Instruction Manual 60mm Alignthefronthousing atthetopedge Fit the front housing to the rear housing Ensure the pin connections are aligned Lightlypressuntilyouhearapositiveclick 3 4 5...

Page 45: ...em type 2 pipe or 4 pipe Short press OK button M M M Select what is connected to S1 By default is No function Please see page 40 for details When the main settings are done FC 600 will go to Standby m...

Page 46: ...Play or App Store You will need to follow a few easy steps to create an account and than link your Fan Coil to the Universal Gateway and to the App You can also access the web version on http eu salus...

Page 47: ...t Rename your device and tap Next Now set your Fan Coil accordingly to your system You can choose the OneTouch now or later For more info on oneTouch please check p 35 This will NOT influence your set...

Page 48: ...cooling options on your system Note Steps 16 19 apply ONLY with you have a 2 pipe system and selected Manual heating cooling option Select if you want to use your Fan Coil for heating cooling or both...

Page 49: ...ermostat tile to enter your thermostat Click on thermostat name to enter main screen Click on On Off icon to turn on your thermostat A sub menu will appear on screen tap On to turn on your thermostat...

Page 50: ...g In the table you will find all the settings and their values described 4 7 2 Switching from non programmable to programmable thermostat M Press the buttons for 3 seconds M Press OK You should enter...

Page 51: ...come in a list of dxx names and for each dxx parameter you can choose a specific value that will set the Fan Coil to a specific setting When you accessed Installer Settings a short press of the or wil...

Page 52: ...Auto Heat Cool Changeover the switching betweenheating andcoolingisperformedautomatically User cannot select heating cooling mode by pressing the Mode button In a 2 pipe system Procedure performed by...

Page 53: ...to 40 C 5 C d10 ECO set point in Heating mode This setting is responsible for the ECO setpoint temperature when the thermostat is in Heating mode Can be set to any value from 5 C to 40 C 15 C d11 ECO...

Page 54: ...2 0 d 24 Heat cool changeover cooling switch point Heat cool changeover cooling switch point Heat cool changeover cooling switch point The value of this parameter is used by the pipe temperature sens...

Page 55: ...ction in 0 standby 1 last configuration 0 d37 To allow user unlock the keys or NOT 1 means user can unlock by pressing and 0 means user can NOT unlock by pressing and If d37 0 user can lock unlock the...

Page 56: ...mperature relationship with actual display temperature Expected TPI advantages Self adapt to different environment to find balancing point Fast response to reach set point Auto recovery Fast stable re...

Page 57: ...TPI or SPAN VALVE controlled by TPI or SPAN Tstat work still in cooling mode FAN is OFF VALVE controlled by TPI or SPAN Tstat work in HEATING mode FAN controlled by TPI or SPAN VALVE controlled by TP...

Page 58: ...e user will set another mode eg Permanent hold the Fan Coil will exit ECO mode and follow the selected mode ECO mode STANDBY mode When the Fan Coil is set to d34 1 STANDBY mode and there is no presenc...

Page 59: ...Press OK M Short press button to confirm pairing At this point you should go to the App in order to configure your Fan Coil The antenna sign will appear in the corner of the screen Make sure that you...

Page 60: ...flash red The Fan Coil should appear on screen Select device and tap connect equipment Rename your device and tap Next M The Fan Coil will go automatically into FC App screen Now tap Finish to finish...

Page 61: ...eset by pressing OK Via App Tile is no longer visible The thermostat is removed Go to your thermostat Scroll to bottom of the screen tap Remove Tap delete Note If you reseted your thermostat on your d...

Page 62: ...y offset range From 3 0 to 3 0 in 0 5 steps Frost protection point Yes Overheat protection Yes Temperature sampling duration Every 15 seconds Multifunctional input S1 M S2 M Temperature sensor input T...

Page 63: ...perform in accordance with its specification for a period of two years from the date of installation SALUS Controls sole liability for breach of this warranty will be at its option to repair or repla...

Page 64: ...4 0 1226 323961 E tech salus tech com www salus controls com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserves the ri...