7
2.5 Mounting and installation of the thermostat
*TPI is a built-in energy-saving control algorithm that ensures a
stable temperature in the rooms.
**The NSB function is only available if the system is equipped with
at least one weekly programmable thermostat (master). There is no
need to remove the jumper in case there is no master thermostat.
***If a programmable thermostat (master) is connected to the
system and the NSB function is active, the HTR-RF(20) thermostat
will automatically adjust the temperature decrease value according
to the jumper settings.
Jumper
Function
Default
TPI*/Hysteresis
TPI (jumper on) or
Hysteresis 0.5°C (jumper
off)
TPI on
NSB function**
NSB on (jumper on) or off
(jumper off)
On
NSB temperature
decrease value***
-2°C (jumper on) or -4°C
(jumper off)
-2°C for heating mode
+2°C for cooling mode
1
2
Adjust the settings with the
jumpers.
3
NSB TPI
2°C ON
ON
4°C OFF OFF
Jumper on
Jumper off
Make sure the thermostat
knob is in position 1.
Then insert the batteries. When done,
place the thermostat on the back
cover that is attached to the wall.
4
5
Remove back cover.
Mount the back cover to the wall
using screws included with the
set.