66
3 sec.
3 sec.
9. Installer parameters
To enter installer parameters please follow steps below. Please refer to parameters table description before any changes. Use
or
buttons to move
up or down between all parameters. Every change/selection confirm by button:
1
3
Use
or
to choose
code „49”.
Press button to confirm.
Select installer parameter by or
buttons. Use
or
buttons to
change parameter value. Confirm
choice by button.
4
2
Hold + buttons for 3 seconds
to enter the installer mode.
dXX
Function
Parameter
Values
Description
Default
Values
d00
Temperature unit
0
Celsius [°C]
0
1
Fahrenheit [°F]
d01
The method of controlling the
temperature of the heating
system
0
by TPI algorithm
0
1
SPAN ±0.5°C
2
SPAN ±1.0°C
d02
Correction of the displayed
temperature
from -3.0°C
to +3.0°C
If the thermostat indicates an incorrect temperature,
it can be corrected by ± 3.0°C
0°C
d03
Floor temperature sensor use
(S1,S2)
0
No sensor
0
1
Temperature sensor connected
2
Dew point sensor connected (only in UFH)
3
Occupancy sensor connected
3